Evidence map›Paper›PMID 37647399›Full record

ArticleScience advances2023

Optimal sparsity allows reliable system-aware restoration of fluorescence microscopy images.

Biagio Mandracchia, Wenhao Liu, Xuanwen Hua, Parvin Forghani, Soojung Lee, Jessica Hou, Shuyi Nie, Chunhui Xu, Shu Jia

Abstract read
In one paragraph

Article in Science advances, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Biagio MandracchiaWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.ORCID 0000-0002-4583-4733
Wenhao LiuWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.
Xuanwen HuaWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.ORCID 0000-0002-5946-0808
Parvin ForghaniDepartment of Pediatrics, School of Medicine, Emory University, Atlanta, GA, USA.ORCID 0000-0001-9727-3344
Soojung LeeWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.ORCID 0000-0001-6726-878X
Jessica HouSchool of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA.ORCID 0009-0006-5341-2537
Shuyi NieSchool of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA.ORCID 0000-0002-0495-7104
Chunhui XuDepartment of Pediatrics, School of Medicine, Emory University, Atlanta, GA, USA.ORCID 0000-0003-1748-0648
Shu JiaWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.ORCID 0000-0001-6854-7537

Funding

Atlanta Clinical and Translational Science Institute (ACTSI) RenewalUL1TR000454 · NCATS · EMORY UNIVERSITY · PI STEPHENS, DAVID S · 2012 to 2016
$25.8M
Toward Systems Biophotonics: Imaging Biology across High Dimensions and ScalesR35GM124846 · NIGMS · STATE UNIVERSITY NEW YORK STONY BROOK · PI Shu Jia · 2017 to 2026
$4.0M
Alcohol-induced cardiac injury and repair in human induced pluripotent stem cell modelR01AA028527 · NIAAA · EMORY UNIVERSITY · PI XU, CHUNHUI · 2021 to 2025
$1.8M
Functional screen for genetic causes of hypoplastic left heart syndromeR21HD110918 · NICHD · GEORGIA INSTITUTE OF TECHNOLOGY · PI JIA, SHU, NIE, SHUYI · 2023 to 2024
$391k
NCATS NIH HHS UL1 TR000454NIAAA NIH HHS R01 AA028527NICHD NIH HHS R21 HD110918NIGMS NIH HHS R35 GM124846
6 · The paper itself

Abstract

Fluorescence microscopy is one of the most indispensable and informative driving forces for biological research, but the extent of observable biological phenomena is essentially determined by the content and quality of the acquired images. To address the different noise sources that can degrade these images, we introduce an algorithm for multiscale image restoration through optimally sparse representation (MIRO). MIRO is a deterministic framework that models the acquisition process and uses pixelwise noise correction to improve image quality. Our study demonstrates that this approach yields a remarkable restoration of the fluorescence signal for a wide range of microscopy systems, regardless of the detector used (e.g., electron-multiplying charge-coupled device, scientific complementary metal-oxide semiconductor, or photomultiplier tube). MIRO improves current imaging capabilities, enabling fast, low-light optical microscopy, accurate image analysis, and robust machine intelligence when integrated with deep neural networks. This expands the range of biological knowledge that can be obtained from fluorescence microscopy.

Indexed as

AlgorithmsElectronsImage Processing, Computer-AssistedMicroscopy, FluorescenceNeural Networks, Computer

Identifiers

PMID37647399
PMCPMC10468132

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.