Evidence map›Paper›PMID 37647324›Full record

ArticlePloS one2023

Cytocompatibility of titanium and poly(etheretherketone) surfaces after O2 non-thermal plasma sterilization.

Christina Maillet, Florence M Klein, Florian Le Bras, Frederic Velard, Christine Guillaume, Sophie C Gangloff, Marie-Paule Gelle

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Christina MailletBIOS EA 4691, Biomatériaux et Inflammation en Site Osseux, SFR CAP Santé, FED 4231, Université de Reims Champagne Ardenne, Reims, France.ORCID 0000-0002-4341-7311
Florence M KleinUFR Pharmacie, Aurora Cold Plasma Sterilisation, Reims, France.ORCID 0000-0002-0483-3662
Florian Le BrasBIOS EA 4691, Biomatériaux et Inflammation en Site Osseux, SFR CAP Santé, FED 4231, Université de Reims Champagne Ardenne, Reims, France.ORCID 0000-0003-3671-530X
Frederic VelardBIOS EA 4691, Biomatériaux et Inflammation en Site Osseux, SFR CAP Santé, FED 4231, Université de Reims Champagne Ardenne, Reims, France.
Christine GuillaumeBIOS EA 4691, Biomatériaux et Inflammation en Site Osseux, SFR CAP Santé, FED 4231, Université de Reims Champagne Ardenne, Reims, France.
Sophie C GangloffBIOS EA 4691, Biomatériaux et Inflammation en Site Osseux, SFR CAP Santé, FED 4231, Université de Reims Champagne Ardenne, Reims, France.ORCID 0000-0003-2651-9372
Marie-Paule GelleBIOS EA 4691, Biomatériaux et Inflammation en Site Osseux, SFR CAP Santé, FED 4231, Université de Reims Champagne Ardenne, Reims, France.ORCID 0000-0003-1569-7085
Biomatériaux et Inflammation en Site Osseux · FRCentre Hospitalier Universitaire de Reims · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The sterilization of medical devices is paramount to achieve an acceptable level of sterility assurance and to prevent hospital-acquired infections. However, some medical devices cannot be sterilized by usual processes such as autoclave (AC) and gamma-ray irradiation (GI). A new non-thermal plasma (NTP) process using sealed bag that preserves the sterile state of the devices could be used as an alternative sterilization method. The aim of the study was to assess the cytocompatibility of titanium and poly(etheretherketone) (PEEK) surfaces after O2-NTP sterilization compared to GI and AC. MG-63 osteoblast-like cells were seeded on titanium (TA6V) and PEEK disks sterilized by AC, GI and O2-NTP. The cells' viability and proliferation, determined by WST-1 and DNA quantification respectively, were enhanced whatever the material types from 3 to 10 days. When seeded on titanium, MG-63 cells showed a higher viability and proliferation after GI and O2-NTP treatment compared to AC treatment. When cultured on PEEK, MG-63 cells showed a higher viability after O2-NTP treatment. No difference of proliferation was observed whatever the sterilization processes. The cell colonization of the materials' surface was confirmed by scanning electron microscopy. Lactate dehydrogenase (LDH) assay revealed no cytotoxicity. Thus, O2-NTP led to similar cell responses to AC and GI and could be a cost-effective alternative process to the usual sterilization methods for fragile medical devices.

Indexed as

InfertilityPlasma GasesBenzophenonesHumansPoly APolymersSterilizationTitaniumBenzophenonesPlasma GasesPoly ApolyetheretherketonePolymersTitanium

Identifiers

PMID37647324
PMCPMC10468041
OpenAlexW4386280343

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.