Evidence map›Paper›PMID 37646806›Full record

ArticleEuropean radiology2024

The validity of ultrasound and shear wave elastography to assess the quality of the rotator cuff.

Nina H C Peeters, Annick M van der Kraats, Thomas E van der Krieken, Dave van Iersel, Esther R C Janssen, Frederik O Lambers Heerspink

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Guideline
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Nina H C PeetersDepartment of Radiology, VieCuri Medical Center, Venlo, The Netherlands.
Annick M van der KraatsDepartment of Orthopaedic Surgery, VieCuri Medical Center, Tegelseweg 210, 5912 BL, Venlo, The Netherlands.
Thomas E van der KriekenDepartment of Radiology, VieCuri Medical Center, Venlo, The Netherlands.
Dave van IerselDepartment of Radiology, VieCuri Medical Center, Venlo, The Netherlands.
Esther R C JanssenDepartment of Orthopaedic Surgery, VieCuri Medical Center, Tegelseweg 210, 5912 BL, Venlo, The Netherlands. estherjanssen@viecuri.nl.ORCID http://orcid.org/0000-0003-4631-696X
Frederik O Lambers HeerspinkDepartment of Orthopaedic Surgery, VieCuri Medical Center, Tegelseweg 210, 5912 BL, Venlo, The Netherlands.
VieCuri Medisch Centrum · NLMaastricht University Medical Centre · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesUS with shear wave elastography (SWE) could reduce the burden and costs of the diagnostic process for patients with rotator cuff disorders. The aim of this study is to investigate the validity of US and SWE in preoperative assessment of fatty infiltration (FI) and muscle atrophy of the supraspinatus (SSP) and infraspinatus (ISP) muscles.

methodsPatients with a rotator cuff disorder and a recent shoulder CT or MRI scan were eligible to participate. Goutallier and Warner stages of the SSP and ISP muscle were measured on the scan, for assessment of FI and muscle atrophy, respectively. These findings were compared with shear wave velocities (SWVs) assessed on US. Visual assessment of FI on US was compared with the Goutallier stage. To quantify the amount of muscle atrophy, the occupation ratio between SSP fossa and muscle was measured on MRI and US.

resultsSeventy-eight shoulders were included in the analysis. The correlation found between the occupation ratio on US and Warner and Goutallier stage and ratio on MRI ranged between r =  - 0.550 to 0.589. The Goutallier stage of ISP and SSP muscle assessed on US showed a fair correlation with the Goutallier stage on a scan of r = 0.574 and r = 0.582, respectively. There was a poor correlation between the SWVs and scan results (r =  - 0.116 to 0.07).

conclusionSWE is not a valid method to measure the amount of FI or muscle atrophy in the SSP muscle. Therefore, SWE is not a suitable alternative for MRI in standard preoperative diagnostics in rotator cuff pathologies. CLINICAL RELEVANCE STATEMENT: Shear wave elastography should not be used in the diagnostics of rotator cuff pathologies. KEY POINTS: • There is a fair correlation between the Goutallier stage of the supraspinatus and infraspinatus muscle assessed on MRI and CT and visual assessment of fatty infiltration achieved on US. • Shear wave elastography is not a valid tool for the determination of the amount of fatty infiltration or muscle atrophy. • Shear wave elastography should not be used as a cheaper and less burdensome alternative for diagnostics in rotator cuff pathologies.

Indexed as

Elasticity Imaging TechniquesRotator Cuff InjuriesShoulder JointAdipose TissueHumansMagnetic Resonance ImagingMuscular AtrophyRotator CuffShoulderElastographyFatty infiltrationMuscle atrophyRotator cuffUltrasound imaging

Identifiers

PMID37646806
PMCPMC10873448
OpenAlexW4386272411

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.