ArticleMedical physics2023
Pre-whitened matched filter and convolutional neural network based model observer performance for mass lesion detection in non-contrast breast CT.
Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A deep learning anthropomorphic model observer for a detection task in PET.Medical physics · 2024Article
- Microcalcification detectability in breast CT images using CNN observers.Medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
backgroundMathematical model observers have been shown to reasonably predict human observer performance and are useful when human observer studies are infeasible. Recently, convolutional neural networks (CNNs) have also been used as substitutes for human observers, and studies have shown their utility as an optimal observer. In this study, a CNN model observer is compared to the pre-whitened matched filter (PWMF) model observer in detecting simulated mass lesions inserted into 253 acquired breast computed tomography (bCT) images from patients imaged at our institution. PURPOSE: To compare CNN and PWMF model observers for detecting signal-known-exactly (SKE) location-known-exactly (LKE) simulated lesions in bCT images with real anatomical backgrounds, and to use these model observers collectively to optimize parameters and understand trends in performance with breast CT.
methodsSpherical lesions with different diameters (1, 3, 5, 9 mm) were mathematically inserted into reconstructed patient bCT image data sets to mimic 3D mass lesions in the breast. 2D images were generated by extracting the center slice along the axial dimension or by slice averaging across adjacent slices to model thicker sections (0.4, 1.2, 2.0, 6.0, 12.4, 20.4 mm). The role of breast density was retrospectively studied using the range of breast densities intrinsic to the patient bCT data sets. In addition, mass lesions were mathematically inserted into Gaussian images matched to the mean and noise power spectrum of the bCT images to better understand the performance of the CNN in the context of a known ideal observer (the PWMF). The simulated Gaussian and bCT images were divided into training and testing data sets. Each training data set consisted of 91 600 images, and each testing data set consisted of 96 000 images. A CNN and PWMF was trained on the Gaussian training images, and a different CNN and PWMF was trained on the bCT training images. The trained model observers were tested, and receiver operating characteristic (ROC) curve analysis was used to evaluate detection performance. The area under the ROC curve (AUC) was the primary performance metric used to compare the model observers.
resultsIn the Gaussian background, the CNN performed essentially identically to the PWMF across lesion sizes and section thicknesses. In the bCT background, the CNN outperformed the PWMF across lesion size, breast density, and most section thicknesses. These findings suggest that there are higher-order features in bCT images that are harnessed by the CNN observer but are inaccessible to the PWMF.
conclusionsThe CNN performed equivalently to the ideal observer in Gaussian textures. In bCT background, the CNN captures more diagnostic information than the PWMF and may be a more pertinent observer when conducting optimal performance studies in breast CT images.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.