Evidence map›Paper›PMID 37645264›Full record

ArticleHeart rhythm O22023

Comparison between weight-adjusted, high-frequency, low-tidal-volume ventilation and atrial pacing with normal ventilation in high-power, short-duration atrial fibrillation ablation: Results of a pilot study.

Fabricio Vassallo, Joao Pedro Cancellieri, Christiano Cunha, Lucas Corcino, Eduardo Serpa, Aloyr Simoes, Dalton Hespanhol, Carlos Volponi, Dalbian Gasparini, Andre Schmidt

Abstract read
In one paragraph

Article in Heart rhythm O2, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fabricio VassalloCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Joao Pedro CancellieriCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Christiano CunhaCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Lucas CorcinoCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Eduardo SerpaCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Aloyr SimoesCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Dalton HespanholCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Carlos VolponiCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Dalbian GaspariniCardiology Department, Electrophysiology Section, Santa Rita Cassia Hospital, Vitoria, Brazil.
Andre SchmidtCardiology Division, Ribeirao Preto Medical School, University of São Paulo, Ribeirao Preto, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Better contact force (CF) and catheter stability (CS) during atrial fibrillation (AF) ablation are associated with higher success rate. Changes in CF and CS are observed during respiratory movements and cardiac contraction. Previous studies have suggested that rapid atrial pacing (RAP) and high-frequency, low-tidal-volume ventilation (HFLTV) independently or in combination improve CS and CF and quality of lesions. Data from a body weight-adjusted HFLTV strategy associated with RAP in AF high-power, short-duration (HPSD) ablation are still lacking. Objective: This study aimed to compare the results of HPSD AF ablation using simultaneous weight-adjusted HFLTV and RAP and standard ventilation (SV) protocol. Methods: This was a prospective, nonrandomized study with 136 patients undergoing de novo ablation were divided into 2 groups: 70 in RAP (100 ppm) + HFLTV with 4 mL/kg of tidal volume and 25 breaths/min (group A) and 66 patients with SV in intrinsic sinus rhythm (group B). The ablation used 50 W, CF of 5 to 10 g and 10 to 20 g, and 40 mL/min flow rate on the posterior and anterior left atrial walls, respectively. Results: There were no procedure-related complications. In group A, left atrial and total ablation times were 53.5 ± 8.3 minutes and 67.4 ± 10.1 minutes, respectively. Radiofrequency time was 19.7 ± 5.7 minutes, radioscopy time was 3.4 ± 1.8 minutes, 62 (88.6%) patients had first-pass isolation, 23 (33.3%) patients had elevation of luminal esophageal temperature, and 7 (10%) patients had recurrence. In group B, left atrial time was 56.7 ± 10.8 minutes, total ablation time was 72.4 ± 11.5 minutes, radiofrequency time was 22.4 ± 6.2 minutes, radioscopy time was 3.6 ± 3 minutes, 58 (87.9%) patients had first-pass isolation, and 20 (30.3%) patients had luminal esophageal temperature elevation. Conclusion: Weight-adjusted HFLTV with RAP in comparison with SV and intrinsic sinus rhythm in HPSD ablation is safe with no CO

Indexed as

Atrial fibrillationCatheter ablationContact forceHigh-frequency ventilation and rapid pacingHigh powershort duration

Identifiers

PMID37645264
PMCPMC10461207

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.