ArticleHeliyon2023
Effect of modified high-flow oxygen therapy on positive end-expiratory pressure and end-expiratory lung volume based on simulated lung platform.
Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Application of the integrated airway humidification device enhances the humidification effect of the rabbit tracheotomy model.Open life sciences · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: The aim of this study was to assess the effect of modified high-flow oxygen therapy on end-expiratory lung volume (EELV) and positive end-expiratory pressure (PEEP) in tracheotomized patients with normal pulmonary, acute hypoxic respiratory failure (AHRF) or chronic obstructive pulmonary disease (COPD). Methods: A ventilator and an artificial lung model were used to simulate the normal or strong inspiratory effort state of normal lung, AHRF and COPD patients. The traditional high-flow respiratory humidification therapy device connected with a standard interface (group A), and the modified therapy device added two types of resistance valves (group B, inner diameter 7.7 mm, length 24.0 mm; group C, inner diameter 7.7 mm, length 34.0 mm) to the exhalation end of the standard interface. The changes of end-expiratory lung volume (ΔEELV) and PEEP with the increase of flow rate (10 L/min, 20 L/min, 30 L/min, 40 L/min, 50 L/min, 60 L/min) in the three groups was recorded. Results: Under simulated conditions of normal lung, AHRF and COPD, as the flow rate increased by using the modified therapy device, the PEEP values in all groups showed an exponential increasing trend, and the ΔEELV also increased accordingly. In addition, under the same flow rate level, the PEEP values of the two modified high-flow oxygen therapies (Group B and Group C) were significantly higher than those of the standard high-flow oxygen therapy (Group A) ( Conclusion: The addition of different types of resistance valves to the high-flow exhalation end may be a feasible solution to improve the clinical efficacy of tracheotomized high-flow oxygen therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials