Effect of modified high-flow oxygen therapy on positive end-expiratory pressure and end-expiratory lung volume based on simulated lung platform.

Kunming Cheng, Wanqing Li, Yanqiu Lu, Haiyang Wu, Jianxin Zhou

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Kunming ChengDepartment of Intensive Care Unit, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Wanqing LiDepartment of Operating Room, Xiangyang Central Hospital, Affiliated Hospital of Hubei University of Arts and Science, Xiangyang, China.
Yanqiu LuDepartment of Intensive Care Unit, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Haiyang WuDepartment of Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China.
Jianxin ZhouDepartment of Critical Care Unit, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China.
Second Affiliated Hospital of Zhengzhou University · CNCapital Medical University · CNHubei University of Arts and Science · CNTianjin Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The aim of this study was to assess the effect of modified high-flow oxygen therapy on end-expiratory lung volume (EELV) and positive end-expiratory pressure (PEEP) in tracheotomized patients with normal pulmonary, acute hypoxic respiratory failure (AHRF) or chronic obstructive pulmonary disease (COPD). Methods: A ventilator and an artificial lung model were used to simulate the normal or strong inspiratory effort state of normal lung, AHRF and COPD patients. The traditional high-flow respiratory humidification therapy device connected with a standard interface (group A), and the modified therapy device added two types of resistance valves (group B, inner diameter 7.7 mm, length 24.0 mm; group C, inner diameter 7.7 mm, length 34.0 mm) to the exhalation end of the standard interface. The changes of end-expiratory lung volume (ΔEELV) and PEEP with the increase of flow rate (10 L/min, 20 L/min, 30 L/min, 40 L/min, 50 L/min, 60 L/min) in the three groups was recorded. Results: Under simulated conditions of normal lung, AHRF and COPD, as the flow rate increased by using the modified therapy device, the PEEP values in all groups showed an exponential increasing trend, and the ΔEELV also increased accordingly. In addition, under the same flow rate level, the PEEP values of the two modified high-flow oxygen therapies (Group B and Group C) were significantly higher than those of the standard high-flow oxygen therapy (Group A) ( Conclusion: The addition of different types of resistance valves to the high-flow exhalation end may be a feasible solution to improve the clinical efficacy of tracheotomized high-flow oxygen therapy.

Indexed as

End-expiratory lung volumeHigh flow oxygen therapyPositive end-expiratory pressureTracheotomy

Identifiers

PMID37636410
PMCPMC10450983
OpenAlexW4385777648

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.