Evidence map›Paper›PMID 37636323›Full record

ArticleMicrosystems & nanoengineering2023

Flexible thermoelectric generator and energy management electronics powered by body heat.

Shuai Yang, Yumei Li, Ling Deng, Song Tian, Ye Yao, Fan Yang, Changlei Feng, Jun Dai, Ping Wang, Mingyuan Gao

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shuai YangCollege of Engineering and Technology, Southwest University, 400716 Chongqing, China.
Yumei LiCollege of Engineering and Technology, Southwest University, 400716 Chongqing, China.
Ling DengCollege of Engineering and Technology, Southwest University, 400716 Chongqing, China.
Song TianCollege of Engineering and Technology, Southwest University, 400716 Chongqing, China.
Ye YaoGies College of Business, University of Illinois at Urbana-Champaign, Champaign, IL 61820 USA.
Fan YangDepartment of Orthopedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 200025 Shanghai, China.
Changlei FengSchool of Mechatronical Engineering, Beijing Institute of Technology, 100081 Beijing, China.
Jun DaiSchool of Mechatronical Engineering, Beijing Institute of Technology, 100081 Beijing, China.
Ping WangSchool of Civil Engineering, Southwest Jiaotong University, 610031 Chengdu, China.
Mingyuan GaoCollege of Engineering and Technology, Southwest University, 400716 Chongqing, China.ORCID 0000-0002-2207-0419

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Uninterrupted, efficient power supplies have posed a significant hurdle to the ubiquitous adoption of wearable devices, despite their potential for revolutionizing human‒machine interactions. This challenge is further compounded by the requirement of these devices to supply dependable energy for data-intensive sensing and transmission. Traditional thermoelectric solutions fail to deliver satisfactory performance under conditions of extremely low voltages. Here, we present a novel solution of a wearable thermoelectric generator integrated with an energy management system, which is capable of powering sensors and Bluetooth by harnessing body heat. Distinct from previous works, our innovation lies in its ability to consistently operate even with a minimal temperature difference (i.e., 4 K) between the human skin and the ambient environment, ensuring reliable data transmission within a time as short as 1.6 s. Furthermore, our system can recharge utilizing body heat under ultralow voltage conditions (30 mV). Our developed system provides a novel pathway for the continuous, reliable monitoring of self-contained wearable devices without depending on batteries.

Indexed as

Electrical and electronic engineeringStructural properties

Identifiers

PMID37636323
PMCPMC10449853

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.