Evidence map›Paper›PMID 37636302›Full record

ArticleFrontiers in cardiovascular medicine2023

Case report: A complex case of valve-in-valve TAVI and left bundle branch pacing for severe aortic regurgitation with partially corrected type A aortic dissection and low ejection fraction.

Peter Marko Mihailovič, David Žižek, Luka Vitez, Primoz Holc, Tomislav Klokočovnik, Matjaž Bunc

Open access · goldAbstract readCase Reports
In one paragraph

Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Peter Marko MihailovičDepartment of Cardiology, University Medical Center Ljubljana, Slovenia.
David ŽižekDepartment of Cardiology, University Medical Center Ljubljana, Slovenia.
Luka VitezDepartment of Cardiology, University Medical Center Ljubljana, Slovenia.
Primoz HolcDepartment of Cardiology, University Medical Center Ljubljana, Slovenia.
Tomislav KlokočovnikDepartment of Cardiovascular Surgery, University Medical Center Ljubljana, Slovenia.
Matjaž BuncDepartment of Cardiology, University Medical Center Ljubljana, Slovenia.
Ljubljana University Medical Centre · SIUniversity of Ljubljana · SI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Aortic regurgitation is a major concern following transcatheter aortic valve implantation (TAVI), as even low-grade regurgitation is associated with increased mortality. This is of particular concern to patients with pre-existing aortic disease who are at increased risk of TAVI valve slippage. Furthermore, conduction system disturbances after TAVI, namely left bundle branch block (LBBB), may have an additional detrimental effect on cardiac function. Case presentation: This report documents a successful treatment strategy in a frail patient with a bicuspid aortic valve and aortic disease after valve-sparing surgical repair in 1998, who subsequently developed aortic stenosis and underwent TAVI with an Evolut R self-expanding aortic valve. The progression of aortic disease, aortic root dilatation, and leaflet degeneration over the following years caused aortic regurgitation of the self-expanding aortic valve, resulting in left ventricular dilatation and heart failure along with LBBB and left ventricular (LV) mechanical dyssynchrony. Diagnostic workup of the patient showed persistence of the aneurysm distal to the graft with a dissection spanning the ascending aorta, arch, and terminating proximal to the aortic isthmus. After consideration by the cardiac team, a balloon-expandable valve was chosen for a valve-in-valve (ViV) procedure to provide sufficient radial force to expand the existing valve and correct the regurgitation. Due to the anatomy, a J-wire and pigtail catheter were successfully used for a safe approach and placement of the valve. Following the procedure, intermittent complete atrioventricular block was observed in addition to the pre-existing left bundle branch block, necessitating resynchronization pacing. Due to anatomical considerations, ease of placement, and the expected good level of resynchronization due to the proximal block, we opted for left bundle branch pacing, which showed improvement in left ventricular dyssynchrony and LV function at follow-up. Conclusion: Valve-in-valve implantation of a balloon-expandable Myval TAVI device to treat aortic regurgitation caused by slippage and right leaflet disfunction of slef valve is feasible in challenging anatomical scenarios. Left bundle branch pacing is a viable alternative to correct mechanical dyssynchrony in complex patients with LBBB and anatomical challenges necessitating resynchronization.

Indexed as

aortic regurgitation (AR)cardiac resychronisation therapyheart failureleft bundle area pacingleft bundle branch pacing (LBBP)transcatheter aortic valve implantation (TAVI)valve in valve implantationvalve in valve transcatheter aortic valve implantation

Identifiers

PMID37636302
PMCPMC10449538
OpenAlexW4385728017

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.