Evidence map›Paper›PMID 37634138›Full record

ArticleAbdominal radiology (New York)2023

Artificial intelligence tool detection of intravenous contrast enhancement using spleen attenuation.

B Dustin Pooler, Cullen J Fleming, John W Garrett, Ronald M Summers, Perry J Pickhardt

Abstract read
PubMed Publisher
In one paragraph

Article in Abdominal radiology (New York), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

B Dustin PoolerDepartment of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA. bpooler@uwhealth.org.ORCID 0000-0002-8719-5976
Cullen J FlemingDepartment of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.
John W GarrettDepartment of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.
Ronald M Summers *Imaging Biomarkers and Computer-Aided Diagnosis Laboratory, Department of Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA.
Perry J Pickhardt *Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.

Funding

National Institutes of Health Clinical Center
6 · The paper itself

Abstract

purposeTo assess the ability of an automated AI tool to detect intravenous contrast material (IVCM) in abdominal CT examinations using spleen attenuation.

methodsA previously validated automated AI tool measuring the attenuation of the spleen was deployed on a sample of 32,994 adult (age ≥ 18) patients (mean age, 61.9 ± 14.7 years; 13,869 men, 19,125 women) undergoing 65,449 supine position CT examinations (41,020 with and 24,429 without IVCM by DICOM header) from January 1, 2000 to December 31, 2021. After exclusions, receiver operating characteristic (ROC) curve analysis was performed to determine the optimal threshold for binary classification of IVCM status (non-contrast vs IVCM enhanced), which was then applied to the sample. Discordant examinations (i.e., IVCM status determined by AI tool did not match DICOM header) were manually reviewed to establish ground truth. Repeat ROC curve and contingency table analysis were performed to assess AI tool performance.

resultsROC analysis of the initial study sample of 61,783 CT examinations yielded AUC of 0.970 with Youden index suggesting an optimal spleen attenuation threshold of 65 Hounsfield units (HU). Manual review of 2094 discordant CT examinations revealed discordance due to DICOM header error in 1278 (61.0%) and AI tool misclassification in 410 (19.6%), with 406 (9.4%) meeting exclusion criteria. Analysis of 61,377 CT examinations in the final study sample yielded AUC of 0.999 with accuracy of 99.3% at the 65 HU threshold. Error rate for DICOM header information was 2.1% (1278/61,377) versus 0.7% (410/61,377) for the AI tool.

conclusionThe automated spleen attenuation AI tool was highly accurate for detection of IVCM at a threshold of 65 HU.

Indexed as

Artificial IntelligenceContrast MediaRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedSpleenTomography, X-Ray ComputedAgedFemaleHumansMaleMiddle AgedRetrospective StudiesContrast MediaArtificial intelligenceAttenuationContrastCTSpleen

Identifiers

PMID37634138

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.