Evidence map›Paper›PMID 37631841›Full record

ArticleSensors (Basel, Switzerland)2023

Force-Position Hybrid Compensation Control for Path Deviation in Robot-Assisted Bone Drilling.

Shibo Li, Xin Zhong, Yuanyuan Yang, Xiaozhi Qi, Ying Hu, Xiaojun Yang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shibo LiGuangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID 0000-0001-8398-4102
Xin ZhongGuangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Yuanyuan YangGuangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID 0000-0002-0623-636X
Xiaozhi QiGuangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID 0000-0001-6010-3974
Ying HuGuangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Xiaojun YangSchool of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen 518055, China.

Funding

Joint Funds of the National Natural Science Foundation of China U21A20489National Natural Science Foundation of China 62003330Shenzhen Fundamental Research Funds JCYJ20200109114233670Shenzhen Fundamental Research Funds JCYJ20220818101608019
6 · The paper itself

Abstract

Bone drilling is a common procedure in orthopedic surgery and is frequently attempted using robot-assisted techniques. However, drilling on rigid, slippery, and steep cortical surfaces, which are frequently encountered in robot-assisted operations due to limited workspace, can lead to tool path deviation. Path deviation can have significant impacts on positioning accuracy, hole quality, and surgical safety. In this paper, we consider the deformation of the tool and the robot as the main factors contributing to path deviation. To address this issue, we establish a multi-stage mechanistic model of tool-bone interaction and develop a stiffness model of the robot. Additionally, a joint stiffness identification method is proposed. To compensate for path deviation in robot-assisted bone drilling, a force-position hybrid compensation control framework is proposed based on the derived models and a compensation strategy of path prediction. Our experimental results validate the effectiveness of the proposed compensation control method. Specifically, the path deviation is significantly reduced by 56.6%, the force of the tool is reduced by 38.5%, and the hole quality is substantially improved. The proposed compensation control method based on a multi-stage mechanistic model and joint stiffness identification method can significantly improve the accuracy and safety of robot-assisted bone drilling.

Indexed as

Orthopedic ProceduresOrthopedicsRoboticsbone drillingcompensation controlpath deflectionrobot-assisted surgerystiffness model

Identifiers

PMID37631841
PMCPMC10458884

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.