ArticleSensors (Basel, Switzerland)2023
A Novel Tandem Differential Edge Sensor Layout for Segmented Mirror Telescopes.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The performance of an active control system, crucial for the co-phase maintenance of segmented mirrors, is closely related to the spatial layout of sensors and actuators. This article compares two types of edge sensor layouts, vertical and horizontal, and proposes a novel tandem differential sensor layout that saves layout space and reduces the number of positioning references. The control performance of this scheme is analyzed in terms of error propagation, mode representation, and the scalable construction of the control matrix. Finally, we constructed a tandem differential-based sensor detection system to examine the performance of edge sensors and the effect of laboratory environmental variables on sensor measurements. Simulations and experiments demonstrate that this scheme has the same ability to fully characterize actuator modification modes as the Keck edge sensor layout. Although the total error multiplier is slightly larger than the latter, it has fewer scalable control matrix types and stronger spatial and segmental shape adaptation capabilities. Actual measurements show that the sensor's own noise in a tandem differential layout is less than 20 nm, which meets the requirements for future segmented co-phase maintenance. This layout type can potentially be applied to future small and medium-sized segmented splices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.