ArticleSensors (Basel, Switzerland)2023
Calibration Method of a Wideband AC Resistance Voltage Divider Based on an Equivalent Model.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Aiming at the problem of large measurement error and phase shift in resistance voltage dividers under high-frequency conditions in the field of power measurement, such as power harmonics, an error correction method is proposed for an alternating current (AC) resistance voltage divider based on the equivalence principle. Firstly, the frequency error model of the AC resistance voltage divider precision is established, and the angle difference of the continuous spectrum ratio difference from 50 Hz to 100 kHz is corrected by determining the shielding structure and the resistance parameters and fine-tuning the shielding potential correction method to reduce the capacities error of the AC resistance voltage divider design precision. At the same time, the performance parameters such as the direction and magnitude of the shielding potential compensation capacitive error are investigated. Finally, the precision voltage divider (the maximum voltage applied is 480 V) calibration experiments verify that the important characteristic judgment factor of the voltage divider is independent of the frequency and the equivalent capacitance value, which effectively solves the phase correction problem of harmonic power measurement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.