Evidence map›Paper›PMID 37631704›Full record

ArticleSensors (Basel, Switzerland)2023

Investigation of the Relationship between Body Parameters and mAs Using Non-Contact Two-Dimensional Thickness Measurement in Chest Digital Radiography.

Jia-Ru Lin, I-Hao Cheng, Yu-Syuan Liang, Jyun-Jie Li, Jen-Ming Tsai, Min-Tsung Wang, Te-Pao Lin, Su-Lan Huang, Ming-Chung Chou

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Machine learning for optimizing mAs in KUB radiography with metal implants.Journal of applied clinical medical physics · 2026
    Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jia-Ru LinDepartment of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
I-Hao ChengDepartment of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
Yu-Syuan LiangDepartment of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan.
Jyun-Jie LiDepartment of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
Jen-Ming TsaiDepartment of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
Min-Tsung WangDepartment of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
Te-Pao LinDepartment of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
Su-Lan HuangDepartment of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
Ming-Chung ChouDepartment of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung 807, Taiwan.ORCID 0000-0001-8488-2693

Funding

Kaohsiung Armed Forces General Hospital 107-26Ministry of Science and Technology MOST110-2314-B-037-077-MY3
6 · The paper itself

Abstract

The current study aimed to investigate the relationship between body parameters and the current-time product (mAs) in chest digital radiography using a non-contact infrared thickness-measurement sensor. An anthropomorphic chest phantom was first used to understand variations in mAs over multiple positionings during chest radiography when using the automatic exposure control (AEC) technique. In a human study, 929 consecutive male subjects who underwent regular chest examinations were enrolled, and their height (H), weight (W), and body mass index (BMI) were recorded. In addition, their chest thickness (T) was measured at exhalation using a non-contact infrared sensor, and chest radiography was then performed using the AEC technique. Finally, the relationship between four body parameters (T, BMI, T*BMI, and W/H) and mAs was investigated by fitting the body parameters to mAs using three curve models. The phantom study showed that the maximum mAs was 1.76 times higher than the lowest mAs during multiple positionings in chest radiography. In the human study, all chest radiographs passed the routine quality control procedure and had an exposure index between 100 and 212. In curve fitting, the comparisons showed that W/H had a closer relationship with mAs than the other body parameters, while the first-order power model with W/H fitted to mAs performed the best and had an R-square of 0.9971. We concluded that the relationship between W/H and mAs in the first-order power model may be helpful in predicting the optimal mAs and reducing the radiation dose for chest radiography when using the AEC technique.

Indexed as

Radiographic Image EnhancementThoraxBody Mass IndexExhalationHumansMaleRadiographyautomatic exposure controlbody parameterschest radiographymAsnon-contact infrared sensor

Identifiers

PMID37631704
PMCPMC10458936

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.