ArticleNanomaterials (Basel, Switzerland)2023
The Slight Adjustment in the Weight of Sulfur Sheets to Synthesize β-NiS Nanobelts for Maintaining Detection of Lower Concentrations of Glucose through a Long-Term Storage Test.
Article in Nanomaterials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 5 institutions in 1 country.
Funding
Abstract
The β-nickel sulfide (β-NiS) nanobelts were fabricated by electrodepositing a nickel nanosheet film on Indium tin oxide (ITO)-coated glass substrates and sulfuring the nickel film on ITO-coated glass substrates. The sulfurization method can be used to form nanobelts without a template. A small glass tube was used to anneal the sulfur sheet with a nickel nanosheet film. After applying vacuum to the tube, the specimen was annealed at 500 °C. By adjusting the weight of the sulfur sheet in a small glass tube, a nanobelt structure can be formed on the film for 4 h. The β-NiS nanobelt film had a sulfide and nickel molar ratio that was nearly 0.7 (S/Ni). After five years of a long-term storage test, the β-NiS nanobelt films were able to measure the glucose in a solution with the value of sensitivity of 8.67 µA cm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.