Evidence map›Paper›PMID 37630181›Full record

ArticleMicromachines2023

Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends.

Anubhav Tiwari, Ishfaq A Ahmed, Vijay Kumar Gupta, Rakesh Kumar Haldkar, Ivan A Parinov

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Anubhav TiwariMachine Dynamics and Vibration Lab, Discipline of Mechanical Engineering, PDPM Indian Institute of Information Technology, Design & Manufacturing, Jabalpur, Dumna Airport Road, Jabalpur 482005, India.ORCID 0000-0001-7964-1123
Ishfaq A AhmedMachine Dynamics and Vibration Lab, Discipline of Mechanical Engineering, PDPM Indian Institute of Information Technology, Design & Manufacturing, Jabalpur, Dumna Airport Road, Jabalpur 482005, India.ORCID 0000-0001-8076-8084
Vijay Kumar GuptaMachine Dynamics and Vibration Lab, Discipline of Mechanical Engineering, PDPM Indian Institute of Information Technology, Design & Manufacturing, Jabalpur, Dumna Airport Road, Jabalpur 482005, India.ORCID 0000-0002-2337-7076
Rakesh Kumar HaldkarI. I. Vorovich Mathematics, Mechanics and Computer Sciences Institute, Southern Federal University, Rostov-on-Don 344090, Russia.ORCID 0000-0002-5176-1470
Ivan A ParinovI. I. Vorovich Mathematics, Mechanics and Computer Sciences Institute, Southern Federal University, Rostov-on-Don 344090, Russia.ORCID 0000-0003-3833-0331
Indian Institute of Information Technology Design and Manufacturing Jabalpur · INSouthern Federal University · RU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The temporomandibular joint (TMJ) is a critical joint for the opening and closing of the mouth. The generation of customised TMJs according to individuals' dental anatomy is needed. Currently, the implants available on the market lack consideration of the patient's dental anatomy. This leads to the creation of an imbalance in the reaction forces on both ends of the TMJ. This requires a slight structural change in the design parameters to give a solution. The purpose of this study is to propose a new design that includes the geometry and materials for a TMJ implant. Stress analysis was carried out on the TMJ to balance the reaction forces at both TMJ ends. A static analysis was performed using ANSYS Workbench, to compare the results of two customised designs of TMJ implants, in order to better balance the reaction forces at both ends. The model in the study showed that the reaction forces for both the patient-specific TMJ implants were nearly balanced. The reaction forces were better balanced, and almost equivalent to the intact conditions. The stresses in the mandible were more uniformly distributed in the customised design of the TMJ implant. The two types of design showed that the custom design took up less space in the patient's region of surgery, making it a better option compared to a stock TMJ implant. The custom implant would allow faster patient rehabilitation, as the reaction forces would be close to those in intact conditions.

Indexed as

customised TMJ implantDICOMisotropicorthotropic

Identifiers

PMID37630181
PMCPMC10458138
OpenAlexW4386029009

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.