Evidence map›Paper›PMID 37630157›Full record

ArticleMicromachines2023

Electrohydrodynamic Printed Ultra-Micro AgNPs Thin Film Temperature Sensors Array for High-Resolution Sensing.

Yingping He, Lanlan Li, Zhixuan Su, Lida Xu, Maocheng Guo, Bowen Duan, Wenxuan Wang, Bo Cheng, Daoheng Sun, Zhenyin Hai

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yingping HeDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Lanlan LiDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Zhixuan SuDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Lida XuDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Maocheng GuoDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Bowen DuanDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Wenxuan WangDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Bo ChengDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Daoheng SunDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.
Zhenyin HaiDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361005, China.

Funding

the National Key Research and Development Program 2021YFB3200701the National Natural Science Foundation of China 62101469
6 · The paper itself

Abstract

Current methods for thin film sensors preparation include screen printing, inkjet printing, and MEMS (microelectromechanical systems) techniques. However, their limitations in achieving sub-10 μm line widths hinder high-density sensors array fabrication. Electrohydrodynamic (EHD) printing is a promising alternative due to its ability to print multiple materials and multilayer structures with patterned films less than 10 μm width. In this paper, we innovatively proposed a method using only EHD printing to prepare ultra-micro thin film temperature sensors array. The sensitive layer of the four sensors was compactly integrated within an area measuring 450 μm × 450 μm, featuring a line width of less than 10 μm, and a film thickness ranging from 150 nm to 230 nm. The conductive network of silver nanoparticles exhibited a porosity of 0.86%. After a 17 h temperature-resistance test, significant differences in the performance of the four sensors were observed. Sensor 3 showcased relatively superior performance, boasting a fitted linearity of 0.99994 and a TCR of 937.8 ppm/°C within the temperature range of 20 °C to 120 °C. Moreover, after the 17 h test, a resistance change rate of 0.17% was recorded at 20 °C.

Indexed as

AgNPselectrohydrodynamic printingtemperature sensors arraythin filmultra-micro

Identifiers

PMID37630157
PMCPMC10456320

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.