ArticleMaterials (Basel, Switzerland)2023
Evaluation of Setting Times of Concrete Using Electro-Mechanical Impedance Sensing Technique.
Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Method for Identifying Hydration Stages of Concrete Based on Embedded Piezo-Ultrasonic Active Sensing Technology.Materials (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
Abstract
This study presents a novel approach to assessing the setting time of concrete using the electro-mechanical impedance (EMI) sensing technique. The proposed method involves the continuous monitoring of EMI changes by embedding a piezoelectric (PZT) sensor directly in the concrete. A comparative analysis was conducted with the conventional penetration resistance test, which utilizes mortar samples extracted from the concrete. As a result of the experiment, the time deviation rate of the setting time was more than 10% in the penetration resistance test using the mortar sample extracted from the same concrete, whereas the time deviation rate of the setting time was up to 1.77% in the EMI sensing technique using the same concrete specimen. This highlights the effectiveness and potential of the EMI sensing technique for an improved evaluation of concrete setting time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.