ArticleJournal of clinical medicine2023
Influences of Increasing Pedicle Screw Diameter on Widening Vertebral Pedicle Size during Surgery in Spinal Deformities in Children and Adolescents without Higher Risk of Pedicle and Vertebral Breaches.
Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 8 citations in OpenAlex.
- Assessing pedicle morphology in pediatric spinal deformity: can magnetic resonance imaging match computed tomography? A systematic review.Spine deformity · 2026Pooled it
- Pooled it
- Association between pedicle screw dimensions and pedicle morphometry in computed tomography scans.Journal of Taibah University Medical Sciences · 2026Article
- Risk factors for pedicle screw loosening: a comprehensive review.Journal of orthopaedic surgery and research · 2025Review
- Integration of Machine Vision Technology in the Treatment of Pediatric Spinal Deformities.Cureus · 2025Article
- From Rib Hump to Baby Hump-Common Questions of Patients Suffering from and Undergoing Treatment for Scoliosis-A Comprehensive Literature Review.Journal of clinical medicine · 2024Review
- Posterior-Only T11 Vertebral Column Resection for Pediatric Congenital Kyphosis Surgical Correction.Medicina (Kaunas, Lithuania) · 2024Article
- Minimally Invasive Controlled Growing Rods for the Surgical Treatment of Early-Onset Scoliosis-A Surgical Technique Video.Journal of personalized medicine · 2024Article
- The Influence of Increased Pedicle Screw Diameter and Thicker Rods on Surgical Results in Adolescents Undergoing Posterior Spinal Fusion for Idiopathic Scoliosis.Journal of clinical medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA very common technique for treating spinal deformities in children and adolescents is the use of segmental screws. In order to obtain proper stability and the best possible correction, the screws must first be precisely inserted. Additional factors influencing the quality and success of the operation are the size and quality of the bone, the skills of the surgeon, and biomechanical factors, i.e., the width and length of the screws used during surgery. Our study was focused on evaluating the effect of increasing the diameter of the instrumented pedicles by pedicle screws and assessing the safety of expanding these pedicles with screws of various sizes in children with spinal deformities during the growth period, using preoperative magnetic resonance imaging and postoperative computed tomography (CT) to assess and compare preoperative size measurements from MRI to postoperative CT measurements.
methodsWe obtained data for evaluation from the available medical records and treatment histories of patients aged 2 to 18 who underwent surgical treatment of spinal deformities in the years 2016-2023. In 230 patients (28 male and 202 female), 7954 vertebral bodies were scanned by preoperative MRI, and 5080 pedicle screws were inserted during surgery, which were then assessed by postoperative CT scan. For the most accurate assessment, patients were classified into three age groups: 2-5 years (Group 1), 6-10 years (Group 2), and 11-18 years (Group 3). In addition, we studied implant subgroups: vertebral bodies with inserted pedicles of screw sizes 5.0 mm and 5.5 mm (Group S), and pedicles of screw sizes 6.0 mm, 6.5 mm, and 7.0 mm (Group L).
resultsThe morphology of pedicles (Lenke classification) analyzed before surgery using MRI was 55.2% type A, 33.8% type B, 4.7% type C, and 6.3% type D. The postoperative lateral and medial breaches were noted, and these did not cause any complications requiring revision surgery. The mean pedicle diameter before surgery for T1-L5 vertebral pedicles was between 3.79 (1.44) mm and 5.68 (1.64) mm. The mean expanding diameter of pedicles after surgery for T1-L5 vertebral pedicles ranged from 1.90 (0.39) mm to 2.92 (0.28) mm, which corresponds to the extension of the pedicle diameter in the mean range of 47% (4.1)-71% (3.0). We noted that the mean vertebral pedicle expansion was 49% in Group 1, 52% in Group 2, and 62% in Group 3 (N.S.), and the mean expansion for 7.0 mm screw pedicles was 78%.
conclusionsOur study confirms that there is a wide range of expansion of the vertebral pedicle during screw insertion (up to 78%) with a low risk of lateral or medial breaches and without an increased risk of complications. The larger the diameter of the screw inserted into the pedicle, the more the pedicle expands. Pedicle measurements by preoperative MRI may be helpful for sufficient reliability in preoperative planning.
Indexed as
Identifiers
What OpenQuestion holds