Evidence map›Paper›PMID 37627825›Full record

ArticleBioengineering (Basel, Switzerland)2023

A Soft-Reference Breast Ultrasound Image Quality Assessment Method That Considers the Local Lesion Area.

Ziwen Wang, Yuxin Song, Baoliang Zhao, Zhaoming Zhong, Liang Yao, Faqin Lv, Bing Li, Ying Hu

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ziwen WangSchool of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen 518055, China.
Yuxin SongShenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Baoliang ZhaoShenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Zhaoming ZhongThe Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China.
Liang YaoShenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Faqin LvThe Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China.
Bing LiSchool of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen 518055, China.ORCID 0000-0002-5055-8921
Ying HuShenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.

Funding

National Key Research and Development Program of China 2022YFB4703500
6 · The paper itself

Abstract

The quality of breast ultrasound images has a significant impact on the accuracy of disease diagnosis. Existing image quality assessment (IQA) methods usually use pixel-level feature statistical methods or end-to-end deep learning methods, which focus on the global image quality but ignore the image quality of the lesion region. However, in clinical practice, doctors' evaluation of ultrasound image quality relies more on the local area of the lesion, which determines the diagnostic value of ultrasound images. In this study, a global-local integrated IQA framework for breast ultrasound images was proposed to learn doctors' clinical evaluation standards. In this study, 1285 breast ultrasound images were collected and scored by experienced doctors. After being classified as either images with lesions or images without lesions, they were evaluated using soft-reference IQA or bilinear CNN IQA, respectively. Experiments showed that for ultrasound images with lesions, our proposed soft-reference IQA achieved PLCC 0.8418 with doctors' annotation, while the existing end-to-end deep learning method that did not consider the local lesion features only achieved PLCC 0.6606. Due to the accuracy improvement for the images with lesions, our proposed global-local integrated IQA framework had better performance in the IQA task than the existing end-to-end deep learning method, with PLCC improving from 0.8306 to 0.8851.

Indexed as

breast ultrasoundimage quality assessmentsoft reference

Identifiers

PMID37627825
PMCPMC10451797

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.