Evidence map›Paper›PMID 37627803›Full record

ArticleBioengineering (Basel, Switzerland)2023

SeizFt: Interpretable Machine Learning for Seizure Detection Using Wearables.

Irfan Al-Hussaini, Cassie S Mitchell

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Machine-learning methods for epilepsy diagnosis and therapeutic prevention: advances, setbacks, and opportunities.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2026
    Review
  2. Article
  3. Wearable Artificial Intelligence for Epilepsy: Scoping Review.Journal of medical Internet research · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Irfan Al-HussainiSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.ORCID 0000-0003-2969-7019
Cassie S MitchellDepartment of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA.ORCID 0000-0002-5472-6355

Funding

Regulatory and Human Study Operations (RHSO) Core CU19AG065169 · NIA · UNIVERSITY OF ARIZONA · PI BRINTON, ROBERTA EILEEN · 2021 to 2025
$59.8M
Inflamm-aging of osteoprogenitor cells: A therapeutic target for improved bone healing - Resubmission - 1 - Revision - 3R01AG056169 · NIA · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI LEUCHT, PHILIPP · 2018 to 2022
$2.4M
Inflamm-aging of osteoprogenitor cells: A therapeutic target for improved bone healingR56AG056169 · NIA · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI LEUCHT, PHILIPP · 2023 to 2023
$347k
NIA NIH HHS R01 AG056169NIA NIH HHS R56 AG056169NIA NIH HHS U19 AG065169NIH HHS U19-AG056169
6 · The paper itself

Abstract

This work presents SeizFt-a novel seizure detection framework that utilizes machine learning to automatically detect seizures using wearable SensorDot EEG data. Inspired by interpretable sleep staging, our novel approach employs a unique combination of data augmentation, meaningful feature extraction, and an ensemble of decision trees to improve resilience to variations in EEG and to increase the capacity to generalize to unseen data. Fourier Transform (FT) Surrogates were utilized to increase sample size and improve the class balance between labeled non-seizure and seizure epochs. To enhance model stability and accuracy, SeizFt utilizes an ensemble of decision trees through the CatBoost classifier to classify each second of EEG recording as seizure or non-seizure. The SeizIt1 dataset was used for training, and the SeizIt2 dataset for validation and testing. Model performance for seizure detection was evaluated using two primary metrics: sensitivity using the any-overlap method (OVLP) and False Alarm (FA) rate using epoch-based scoring (EPOCH). Notably, SeizFt placed first among an array of state-of-the-art seizure detection algorithms as part of the Seizure Detection Grand Challenge at the 2023 International Conference on Acoustics, Speech, and Signal Processing (ICASSP). SeizFt outperformed state-of-the-art black-box models in accurate seizure detection and minimized false alarms, obtaining a total score of 40.15, combining OVLP and EPOCH across two tasks and representing an improvement of ~30% from the next best approach. The interpretability of SeizFt is a key advantage, as it fosters trust and accountability among healthcare professionals. The most predictive seizure detection features extracted from SeizFt were: delta wave, interquartile range, standard deviation, total absolute power, theta wave, the ratio of delta to theta, binned entropy, Hjorth complexity, delta + theta, and Higuchi fractal dimension. In conclusion, the successful application of SeizFt to wearable SensorDot data suggests its potential for real-time, continuous monitoring to improve personalized medicine for epilepsy.

Indexed as

artificial intelligenceaugmentationEEGelectroencephalogramimbalanced classesinterpretabilitymachine learningseizurexai

Identifiers

PMID37627803
PMCPMC10451805

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.