Evidence map›Paper›PMID 37623806›Full record

ArticleMembranes2023

Theoretical Model for the Prediction of Water Flux during the Concentration of an Olive Mill Wastewater Model Solution by Means of Forward Osmosis.

Magdalena Cifuentes-Cabezas, Silvia Álvarez-Blanco, José Antonio Mendoza-Roca, María Cinta Vincent-Vela, José M Gozálvez-Zafrilla

Open access · goldAbstract read
In one paragraph

Article in Membranes, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Magdalena Cifuentes-CabezasInstitute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain.ORCID 0000-0002-3884-4060
Silvia Álvarez-BlancoInstitute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain.ORCID 0000-0003-2372-1858
José Antonio Mendoza-RocaInstitute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain.
María Cinta Vincent-VelaInstitute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain.ORCID 0000-0001-8493-0165
José M Gozálvez-ZafrillaInstitute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain.ORCID 0000-0003-4419-6765
Universitat Politècnica de València · ES

Funding

Ministerio de Ciencia e Innovación 10.13039-7-501100011033
6 · The paper itself

Abstract

Currently, understanding the dynamics of the interaction between the agents in a process is one of the most important factors regarding its operation and design. Membrane processes for industrial wastewater management are not strangers to this topic. One such example is the concentration of compounds with high added value, such as the phenolic compounds present in olive mill wastewater (OMW). This process is a viable option, thanks to the forward osmosis (FO) process, osmotically driven by a saline stream. In this context, the transport of the solute and the solvent through the FO membranes, although essential to the process, remains problematic. This paper presents a study to predict, by means of a theoretical model, the water flux for two membranes (a cellulose triacetate flat sheet and a polyamide hollow fiber with integrated aquaporin proteins) with different characteristics using a sodium chloride solution as the draw solution (DS). The novelty of this model is the consideration of the contribution of organic compounds (in addition to the inorganic salts) to the osmotic pressure in the feed side. Moreover, the geometry of the modules and the characteristics of the membranes were also considered. The model was developed with the ability to run under different conditions, with or without tyrosol (the compound chosen as representative of OMW phenolic compounds) in the feed solution (FS), and was fitted and evaluated using experimental data. The results presented a variability in the model prediction, which was a function of both the membrane used and the FS and DS, with a greater influence of tyrosol observed on the permeate flux in the flat cellulose triacetate membrane.

Indexed as

forward osmosismodelingolive mill wastewatersimulationtyrosol

Identifiers

PMID37623806
PMCPMC10456235
OpenAlexW4386052045

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.