Evidence map›Paper›PMID 37623658›Full record

ArticleJournal of functional biomaterials2023

Antifouling Behavior of Copper-Modified Titania Nanotube Surfaces.

Aniruddha Vijay Savargaonkar, Amit H Munshi, Paulo Soares, Ketul C Popat

Open access · goldAbstract read
In one paragraph

Article in Journal of functional biomaterials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Aniruddha Vijay SavargaonkarDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0009-0005-2680-2233
Amit H MunshiDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.
Paulo SoaresDepartment of Mechanical Engineering, Pontifícia Universidade Católica do Paraná, Curitiba 80215-901, PR, Brazil.ORCID 0000-0001-9325-8139
Ketul C PopatDepartment of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA.ORCID 0000-0002-2417-7789
Colorado State University · USPontifícia Universidade Católica do Paraná · BR

Funding

Superhydrophobic Heart Valve ProsthesisR01HL135505 · NHLBI · OHIO STATE UNIVERSITY · PI DASI, LAKSHMI PRASAD, KOTA, ARUN KUMAR · 2017 to 2020
$2.9M
Nanostructured Surfaces With Improved HemocompatibilityR21EB033511 · NIBIB · GEORGE MASON UNIVERSITY · PI POPAT, KETUL CHANDRAKANT · 2022 to 2023
$410k
NHLBI NIH HHS R01 HL135505NIBIB NIH HHS 1R21EB033511
6 · The paper itself

Abstract

Titanium and its alloys are commonly used to fabricate orthopedic implants due to their excellent mechanical properties, corrosion resistance, and biocompatibility. In recent years, orthopedic implant surgeries have considerably increased. This has also resulted in an increase in infection-associated revision surgeries for these implants. To combat this, various approaches are being investigated in the literature. One of the approaches is modifying the surface topography of implants and creating surfaces that are not only antifouling but also encourage osteointegration. Titania nanotube surfaces have demonstrated a moderate decrease in bacterial adhesion while encouraging mesenchymal stem cell adhesion, proliferation, and differentiation, and hence were used in this study. In this work, titania nanotube surfaces were fabricated using a simple anodization technique. These surfaces were further modified with copper using a physical vapor deposition technique, since copper is known to be potent against bacteria once in contact. In this study, scanning electron microscopy was used to evaluate surface topography; energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy were used to evaluate surface chemistry; contact angle goniometry was used to evaluate surface wettability; and X-ray diffraction was used to evaluate surface crystallinity. Antifouling behavior against a gram-positive and a gram-negative bacterium was also investigated. The results indicate that copper-modified titania nanotube surfaces display enhanced antifouling behavior when compared to other surfaces, and this may be a potential way to prevent infection in orthopedic implants.

Indexed as

antifouling behaviorbiofilm formationtitania nanotube surfaces

Identifiers

PMID37623658
PMCPMC10455356
OpenAlexW4385576302

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.