Evidence map›Paper›PMID 37623352›Full record

ArticleJournal of cardiovascular development and disease2023

Transapical Mitral Valve-in-Ring Replacement Using the Innovative System under 3-Dimensional Printing Guidance.

Yiwei Wang, Yu Mao, Mengen Zhai, Yanyan Ma, Lanlan Li, Yang Liu, Jian Yang

Abstract readCase Reports
In one paragraph

Article in Journal of cardiovascular development and disease, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. First Experience With a Novel Self-Expandable Valve for Mitral Annular Calcification Guided by Three-Dimensional Printing.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yiwei WangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Yu MaoDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Mengen ZhaiDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Yanyan MaDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Lanlan LiDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Yang LiuDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Jian YangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.

Funding

Development and Transformation of New Technology and Construction of Precision Diagnosis and Treatment System for Transcatheter Interventional Diagnosis and Treatment of Structural Heart Diseases 2022YFC2503400Research on Key Techniques of Minimally Invasive Treatment for Valvular Heart Diseases 2023-YBSF-105
6 · The paper itself

Abstract

backgroundTranscatheter mitral valve-in-ring replacement (TMViR) is an emerging alternative for patients with recurrent mitral regurgitation (MR) after a prior failed annuloplasty ring. However, intraoperative common issues and complications remain to be addressed. CASE SUMMARY: We describe the case of a 67-year-old male patient who underwent surgical mitral concomitant tricuspid annuloplasty repair 7 years ago who developed recurrent severe MR (New York Heart Association functional class IV). To avoid a high-risk surgical reoperation, we chose to perform a TMViR using an innovative dedicated device-the Mi-thos system-via a transapical approach. A patient-specific, 3-dimensional printed model was used to guide the procedure to avoid potential challenges. The procedure was performed successfully, and the patient exhibited symptomatic improvement.

conclusionsThis case report highlights the first use of the innovative Mi-thos system in a TMViR procedure. The findings demonstrate the feasibility and safety of utilizing the Mi-thos system, guided by 3-dimensional printing technology, for patients who have experienced recurrent mitral regurgitation MR following a failed annuloplasty ring.

Indexed as

3-dimensional printingfailed annuloplasty ringMi-thos systemtranscatheter mitral valve replacementvalve-in-ring

Identifiers

PMID37623352
PMCPMC10455199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.