Evidence map›Paper›PMID 37622918›Full record

ArticleBiosensors2023

Coupling Capillary-Driven Microfluidics with Lateral Flow Immunoassay for Signal Enhancement.

Pooya Azizian, Jasmina Casals-Terré, Elena Guerrero-SanVicente, Ruta Grinyte, Jordi Ricart, Joan M Cabot

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Pooya AzizianEnergy and Engineering Department, Leitat Technological Center, 08225 Terrassa, Barcelona, Spain.ORCID 0000-0002-6191-6800
Jasmina Casals-TerréMechanical Engineering Department, Technical University of Catalonia, 08222 Terrassa, Barcelona, Spain.ORCID 0000-0002-1368-3950
Elena Guerrero-SanVicenteEnergy and Engineering Department, Leitat Technological Center, 08225 Terrassa, Barcelona, Spain.
Ruta GrinyteEnergy and Engineering Department, Leitat Technological Center, 08225 Terrassa, Barcelona, Spain.
Jordi RicartEnergy and Engineering Department, Leitat Technological Center, 08225 Terrassa, Barcelona, Spain.
Joan M CabotEnergy and Engineering Department, Leitat Technological Center, 08225 Terrassa, Barcelona, Spain.ORCID 0000-0002-3305-078X
Leitat Technological Center · ESUniversitat Politècnica de Catalunya · ES

Funding

AGAUR 2021PROD00064Agencia Estatal de Investigación CPP2021-009021European Union's Horizon 2020 953426Marie Skłodowska Curie 801342Marie Skłodowska-Curie 813863Ministerio de Ciencia y Innovación PID2020-114070RB-I00
6 · The paper itself

Abstract

Microfluidics has emerged as a versatile technology that is applied to enhance the performance of analytical techniques, among others. Pursuing this, we present a capillary-driven microfluidic device that improves the sensitivity of lateral flow immunoassay rapid tests thanks to offering an automated washing step. A novel multilevel microfluidic chip was 3D-printed with a photocurable black resin, sealed by an optically clear pressure-sensitive adhesive, and linked to the lateral flow strip. To depict the efficacy of microfluidics and the washing step, cortisol was measured quantitatively within the proposed device. Measuring cortisol levels is a way to capture physiological stress responses. Among biofluids, saliva is less infectious and easier to sample than others. However, higher sensitivity is demanded because the salivary cortisol concentrations are much lower than in blood. We carried out a competitive lateral flow immunoassay protocol with the difference that the microfluidic device applies an automated washing step after the sample is drained downstream. It washes the trapped quantum-dot-labeled antibodies out from nitrocellulose, diminishing background noise as these are bonded to cortisols and not to the immobilized receptors. Fluorescence spectroscopy, as a high-precision analysis, was successfully applied to determine clinically relevant salivary cortisol concentrations within a buffer quantitatively. The microfluidic design relied on a 3D valve that avoids reagent cross-contamination. This cross-contamination could make the washing buffer impure and undesirably dilute the sample. The proposed device is cost-effective, self-powered, robust, and ideal for non-expert users.

Indexed as

HydrocortisoneMicrofluidicsAntibodiesCathetersImmunoassayAntibodiesHydrocortisone3D-printingcapillary-driven microfluidicscapillary valvecortisolfluorescence spectroscopylateral flow assay

Identifiers

PMID37622918
PMCPMC10452194
OpenAlexW4386032365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.