Evidence map›Paper›PMID 37622877›Full record

ArticleBiosensors2023

Development and Evaluation of a Flexible PVDF-Based Balloon Sensor for Detecting Mechanical Forces at Key Esophageal Nodes in Esophageal Motility Disorders.

Peng Ran, Minchuan Li, Kunlin Zhang, Daming Sun, Yingbing Lai, Wei Liu, Ying Zhong, Zhangyong Li

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. [Development of a balloon sensor device for force-electrical coupling measurement of esophagus].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Peng RanSchool of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Minchuan LiSchool of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Kunlin ZhangSchool of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Daming SunSchool of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Yingbing LaiSchool of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Wei LiuSchool of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Ying ZhongSchool of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
Zhangyong LiChongqing Engineering Research Center of Medical Electronics and Information Technology, Chongqing 400065, China.ORCID 0000-0002-3918-069X
Chongqing University of Posts and Telecommunications · CN

Funding

Natural Science Foundation of Chongqing & General Fund of Chongqing Science and Technology Commission No. cstc2021jcyj-msxmX0864 & No.CSTB2022NSCQ-MSX0006
6 · The paper itself

Abstract

Prevailing methods for esophageal motility assessments, such as perfusion manometry and probe-based function imaging, frequently overlook the intricate stress fields acting on the liquid-filled balloons at the forefront of the probing device within the esophageal lumen. To bridge this knowledge gap, we innovatively devised an infusible flexible balloon catheter, equipped with a quartet of PVDF piezoelectric sensors. This design, working in concert with a bespoke local key-node analytical algorithm and a sensor array state analysis model, seeks to shed new light on the dynamic mechanical characteristics at pivotal esophageal locales. To further this endeavor, we pioneered a singular closed balloon system and a complementary signal acquisition and processing system that employs a homogeneously distributed PVDF piezoelectric sensor array for the real-time monitoring of dynamic mechanical nuances in the esophageal segment. An advanced analytical model was established to scrutinize the coupled physical fields under varying degrees of balloon inflation, thereby facilitating a thorough dynamic stress examination of local esophageal nodes. Our rigorous execution of static, dynamic, and simulated swallowing experiments robustly substantiated the viability of our design, the logical coherence of our esophageal key-point stress analytical algorithm, and the potential clinical utility of a flexible esophageal key-node stress detection balloon probe outfitted with a PVDF array. This study offers a fresh lens through which esophageal motility testing can be viewed and improved upon.

Indexed as

Esophageal Motility DisordersAlgorithmsFluorocarbon PolymersHumansPolyvinylsFluorocarbon Polymerspolyvinylidene fluoridePolyvinylsadvanced infusion-compatible balloon catheteresophageal biomechanical dynamicsesophageal stress analysispolyvinylidene fluoride (PVDF) piezoelectric sensor matrix

Identifiers

PMID37622877
PMCPMC10452430
OpenAlexW4385576203

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.