ArticleApplied bionics and biomechanics2023
Assessing Socket Fit Effects on Pressure and Shear at a Transtibial Residuum/Socket Interface.
Article in Applied bionics and biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 8 citations in OpenAlex.
- Embroidered textile sensors for real-time multiaxial force mapping in prosthetics.Science advances · 2026Article
- Clarifying the landscape of mechanical sensors from stress to strain.Nature sensors · 2026Article
- Patient reported outcomes improve following lower limb prosthesis and socket and replacement.Journal of patient-reported outcomes · 2026Article
- Preliminary development and validation of a textile-based pressure-sensing system for lower-limb prosthetic sockets.Biomedical engineering online · 2026Article
- Mechanical performance analysis of a 3D printing-based transtibial prosthetic socket against the gait cycle using the finite element method.RSC advances · 2025Article
- Skin adaptation in lower limb amputees assessed through Raman spectroscopy and mechanical characterization.Journal of the Royal Society, Interface · 2025Article
- Testing an adjustable prosthetic socket in a simulated military environment.Journal of rehabilitation and assistive technologies engineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Fluctuations in residuum volume during daily activities are known to occur in lower-limb amputees. This can cause frequent changes to fit, which cannot be accommodated by commonly-used prosthetic sockets. The real-time effects, if any, of these minor socket fit changes on interface biomechanics have not been studied extensively. Amputees commonly use different layers of socks to accommodate frequent volume fluctuations, enabling adjustment of socket fit. We, thus, altered socket fit levels via addition/removal of sock layers to a transtibial amputee who habitually-donned two-sock layers to mimic relatively looser and tighter socket fits. Interface pressure and shear sensors were placed at known prominent load-bearing sites of the transtibial residuum/socket interface, i.e., patellar tendon (PT), popliteal fossa (PF), and anterior-distal (AD) end, to measure real-time biomechanical interactions during standing and level walking. Although socket fit level was only slightly modified, changes in interface pressure and shear across anatomical sites were still observed. Tighter fit corresponds to notable pressure reduction at AD during early stance and pressure increase at PT during terminal stance due to the residuum being pushed up. Shear-to-pressure ratios were used to assess comfort, while pressure- and shear-time integrals were used to assess tissue health. We observed more notable changes at tissue sites (e.g., AD and PF). Combined evaluation of pressure and shear, including shear-to-pressure ratio and time integrals, may offer insight for residuum care.
Identifiers
What OpenQuestion holds
Registered trials