ArticleJournal of human hypertension2024
Accuracy of oscillometric-based blood pressure monitoring devices: impact of pulse volume, arrhythmia, and respiratory artifact.
Article in Journal of human hypertension, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 9 citations in OpenAlex.
- Ambulatory blood pressure monitoring in arterial hypertension.Internal and emergency medicine · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
An oscillometric waveform (OMW) envelope-based blood pressure (BP) monitoring device is widely used to monitor blood pressure and prevent hypertension and adverse cardiovascular events. At present, all primary care physicians and clinicians widely recommend oscillometric-based BP devices. The consumer selects the device based on their own decision, without knowing whether the device is validated or not, resulting in over- or under-treatment of hypertension. It is imperative that each device must comply with international protocols. In this study, we have investigated the accuracy of inflation and deflation-based oscillometric BP monitoring devices in the case of sinus rhythm (SR). Since different health conditions of the patient affect the oscillometric waveform, which can affect the device's accuracy, in such cases, many BP monitors are skeptical of succeeding in the norms of international protocols. Therefore, this study also aims to calculate the accuracy of these devices in various health conditions and measure the effect of pulse volume, arrhythmia, and respiratory artifact on it using a non-invasive blood pressure (NIBP) simulator. We found that the oscillometric BP devices failed to measure the correct blood pressure in several clinical conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.