Evidence map›Paper›PMID 37614936›Full record

ArticleCanadian prosthetics & orthotics journal2021

Using a Sweating Residuum/socket Interface Simulator for the Evaluation of Sweat Management Liners in Lower Limb Prosthetics.

M McGrath, K C Davies, A Gallego, P Laszczak, J Tang, S Zahedi, D Moser

Open access · goldAbstract read
In one paragraph

Article in Canadian prosthetics & orthotics journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 64% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. A biofidelic mock residual limb for prosthetic socket testing.Canadian prosthetics & orthotics journal · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

M McGrathBlatchford Group, Unit D Antura, Bond Close, Basingstoke, UK.ORCID https://orcid.org/0000-0003-0195-970X
K C DaviesBlatchford Group, Unit D Antura, Bond Close, Basingstoke, UK.
A GallegoBlatchford Group, Unit D Antura, Bond Close, Basingstoke, UK.
P LaszczakBlatchford Group, Unit D Antura, Bond Close, Basingstoke, UK.
J TangSchool of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, UK.
S ZahediBlatchford Group, Unit D Antura, Bond Close, Basingstoke, UK.
D MoserBlatchford Group, Unit D Antura, Bond Close, Basingstoke, UK.
University of Southampton · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners.

findingsAlthough maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497).

conclusionsThe test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects.

Indexed as

AmputationLower limb prostheticsResidual limbSimulatorSocket interfaceSweating

Identifiers

PMID37614936
PMCPMC10443463
OpenAlexW3139231091

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked