Evidence map›Paper›PMID 37614253›Full record

ArticleCureus2023

Quantifying the Release of Titanium From the Titanium Dioxide-Impregnated Composites Used in Orthodontic Bonding.

Abhishek Sinha, Sweta Gupta, Taruna Taruna, Leena Priya, Awanindra K Jha, Amesh Golwara, Navmi R Gore

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Abhishek SinhaDepartment of Dentistry, Patna Medical College and Hospital, Patna, IND.
Sweta GuptaDepartmental of Orthodontics and Dentofacial Orthopedics, Patna Dental College and Hospital, Patna, IND.
Taruna TarunaDepartment of Public Health Dentistry, Patna Medical College and Hospital, Patna, IND.
Leena PriyaDepartment of Oral Medicine and Radiology, Patna Medical College and Hospital, Patna, IND.
Awanindra K JhaDepartment of Orthodontics and Dentofacial Orthopaedics, Dental College, Rajendra Institute of Medical Sciences (RIMS), Ranchi, IND.
Amesh GolwaraDepartment of Orthodontics and Dentofacial Orthopaedics, Dental College, Rajendra Institute of Medical Sciences (RIMS), Ranchi, IND.
Navmi R GoreDepartment of Dentistry, Dr. Vasantrao Pawar Medical College and Research Center, Nashik, IND.
Manubhai Patel Dental College and Hospital · INPatna Medical College and Hospital · INRajendra Institute of Medical Sciences · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPrevious literature data has extensively assessed the biocompatibility of various orthodontic adhesives and their components, where the results of most of the studies showed cytotoxic effects of different degrees owing to the unbound molecules released structurally from the cured components.

aimThe present in-vitro study was aimed to assess the release of titanium dioxide nanoparticles in the artificial saliva from the orthodontic composites impregnated with titanium dioxide nanoparticles of 5% w/w (weight/weight) and 1% w/w used for metal brackets bonding.

methodsThe study assessed 160 teeth extracted freshly during orthodontic treatment and divided into two groups of 80 samples, each that bonded to orthodontic brackets having 5% w/w and 1% w/w composites with titanium dioxide nanoparticles kept in the artificial saliva. Quantification was done for 5% w/w and 1% w/w composites having titanium nanoparticles with inductively coupled plasma mass spectroscopy at 24 hours, two, four, and six months.

resultsIt was seen that in teeth with 1% titanium dioxide, the greatest titanium release was seen at two months, with non-significant release after two months. In teeth with 5% w/w titanium dioxide nanoparticles showed significant titanium release all the time. A significantly greater titanium dioxide release on increasing concentration from 1% to 5% was seen for the 5% w/w group at all the assessment times.

conclusionThe present study concludes that a higher release of titanium is seen in 5% w/w composite containing titanium dioxide nanoparticles, and the concentrations of 1% and 5% can be safely used and are considered to be within permissible limits.

Indexed as

artificial salivacoupled plasma atomic emission spectroscopynanoparticlesorthodontic bracketstitanium dioxide

Identifiers

PMID37614253
PMCPMC10442466
OpenAlexW4385159018

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.