Evidence map›Paper›PMID 37612567›Full record

ArticleArchives of orthopaedic and trauma surgery2024

PCL preservation or sacrifice does not influence clinical outcomes and survivorship at mid-term follow-up of a J-curve CR total knee replacement with a medial congruent liner and a functional coronal alignment.

Stefano Marco Paolo Rossi, Rudy Sangaletti, Eugenio Jannelli, Davide Bova, Alice Montagna, Francesco Benazzo

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Evaluation of a novel robotic testing method for stability and kinematics of total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Stefano Marco Paolo RossiSezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, UOC Ortopedia e Traumatologia, Fondazione Poliambulanza, Via Bissolati, 57, 25124, Brescia, Italy. rossi.smp@gmail.com.ORCID http://orcid.org/0000-0003-4395-8457
Rudy SangalettiSezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, UOC Ortopedia e Traumatologia, Fondazione Poliambulanza, Via Bissolati, 57, 25124, Brescia, Italy.
Eugenio JannelliClinica Ortopedica e Traumatologica, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy.
Davide BovaU.O. Ortopedia e Traumatologia, Humanitas Mater Domini, Castellanza, Italy.
Alice MontagnaSezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, UOC Ortopedia e Traumatologia, Fondazione Poliambulanza, Via Bissolati, 57, 25124, Brescia, Italy.
Francesco BenazzoSezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia dello Sport, UOC Ortopedia e Traumatologia, Fondazione Poliambulanza, Via Bissolati, 57, 25124, Brescia, Italy.
Fondazione Poliambulanza Istituto Ospedaliero · ITHumanitas Mater Domini · ITIstituto Universitario di Studi Superiori di Pavia · ITPoliclinico San Matteo Fondazione · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn recent years, increasing interest has arisen for medial pivoting TKA implants, designed to mimic the physiological knee kinematics, maximizing the contact area on the medial compartment of the knee, increasing anterior-posterior stability, and contributing to a ball-in-socket effect that allows the posterior cruciate sacrifice without a post-CAM mechanism. The medial congruent liner works with a J-curve cruciate-retaining (CR) femur without a real ball-in-socket design. The aim of this study was to evaluate the clinical outcomes and survival of these implants, with or without PCL sparing, at a medium follow-up.

methodsBetween October 2016 and October 2018, 165 TKRs were performed in 161 patients (69.2% females and 30.8% males) and prospectively followed. Mean follow-up was 72 ± 12 months. All surgeries were performed using an extramedullary device and the same prosthetic implant. Patients were matched in two groups: in 80 patients, the PCL was preserved; in 85 patients, the PCL was sacrificed with a reduction of the tibial slope.

resultsThe OKS and KSS improved in both groups. The difference between the two groups at the final follow-up was not statistically significant. Good-to-excellent clinical results according to the KSS were achieved in 93% of the knees in the PCP group and in 95% in the PCS group. At final follow-up, the Forgotten Joint Score (FJS) was 73.6 in the PCP group and 74.1 in the PCS group with no statistical difference between the two groups (P > 0.05).

conclusionsTKA with a medially congruent insert, showed promising results at mid-term follow-up, PCL preservation or sacrifice did not affect the clinical outcomes and survival. Further follow-up will be needed to evaluate these results at long term.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneePosterior Cruciate LigamentBiomechanical PhenomenaFemaleFollow-Up StudiesHumansKnee JointMaleRange of Motion, ArticularSurvivorshipCRKneeFunctional alignmentJ-CurveMedial congruentPCLTotal knee replacement

Identifiers

PMID37612567
OpenAlexW4386116223

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.