Evidence map›Paper›PMID 37610604›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

Development and assessment of novel assist device for cardiac cannulation.

Elizabeth Fischer, Mikias Gebremeskel, Kochai Jan Jawed, Mahmut Ozturk, Kevin Cleary, Can Yerebakan

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 89% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Elizabeth Fischer *Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, Washington, D.C., USA. emfischer2@childrensnational.org.ORCID http://orcid.org/0000-0001-5967-3072
Mikias Gebremeskel *Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, Washington, D.C., USA.
Kochai Jan JawedSheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, Washington, D.C., USA.
Mahmut OzturkDivision of Cardiovascular Surgery, Children's National Hospital, Washington, D.C., USA.
Kevin ClearySheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, Washington, D.C., USA.
Can YerebakanDivision of Cardiovascular Surgery, Children's National Hospital, Washington, D.C., USA.
Children's National · US

Funding

Development of a novel method for cannulation in pediatric cardiac proceduresR21HD105965 · NICHD · CHILDREN'S RESEARCH INSTITUTE · PI YEREBAKAN, CAN · 2021 to 2022
$437k
Eunice Kennedy Shriver National Institute of Child Health and Human Development R21HD105965
6 · The paper itself

Abstract

purposeCongenital heart defects are the most common birth defects in the USA and in 25% of cases need to be treated with cardiovascular interventions. One of such interventions is the postoperative use of an extracorporeal membrane oxygenation (ECMO) machine for the treatment of cardiorespiratory failure. The process of placing the patient on the ECMO is extremely time-critical and requires the use of cardiac cannulation. For the first time, our team developed and evaluated a new quick-connect cannulation system that allows for rapid, easy, and safe ECMO cannulation in the pediatric population. The design should eliminate the need for purse-string sutures that are currently used to secure cannulas, as the cannulas will be inserted through a port that is glued to the cardiovascular tissue.

methodsThe rapid cannulation assistance device was designed on the SolidWorks computer-aided design software using the dimensions of the commercially available arterial and venous catheters. These designs were then 3D printed, and tensile testing was performed. Then, a flow loop was developed, and cannulation was performed and analyzed on both 3D-printed hearts and porcine hearts.

resultsThe rapid cannulation assistance device was designed and 3D printed. Tensile testing found that the parts were strong enough to withstand forces that may be introduced in studies. 3D-printed and porcine heart tests with a flow loop found no leakage with the 3D-printed hearts but minimal leaking with the porcine hearts. However, this leakage was observed at the junction between the device and the heart, leading us to believe that a glue better suited to attach the device to the heart would prevent leakage in the future.

conclusionsThis project successfully demonstrated how a rapid cannulation assistance device could be developed and tested. Future studies will be conducted that address device adhesion to the cardiovascular tissue so that accurate pressure and flow rates can be measured. Future studies will also include testing the device in a fluid environment to more effectively analyze the device success and comparing the time required to cannulate using our device compared to the standard of care.

Indexed as

Extracorporeal Membrane OxygenationHeart FailureAnimalsArteriesCatheterizationChildHumansLungSwineCardiac cannulationECMOMedical device

Identifiers

PMID37610604
OpenAlexW4386084429

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.