ReviewInnovation (Cambridge (Mass.))2023
Flexible electronics for cardiovascular healthcare monitoring.
Review in Innovation (Cambridge (Mass.)), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 40 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
40 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Impact of Electrical Stimulation on Mental Stress, Depression, and Anxiety: A Systematic Review.Sensors (Basel, Switzerland) · 2025Pooled it
- Wearable Flexible Sensors for Cardiovascular Disease Monitoring.Advanced materials (Deerfield Beach, Fla.) · 2026Review
- Research Progress of LaMicromachines · 2026Review
- Exploring Wide-Range Alkyl Bridge Length Variations in Polymer Semiconductors: From Pristine to Blend Films for High-Mobility Stretchable TFTs.Small (Weinheim an der Bergstrasse, Germany) · 2026Article
- Wearable and Implantable Devices for Continuous Monitoring of Muscle Physiological Activity: A Review.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Curvy Surface Reconstruction.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Ionogel-based flexible electronics.National science review · 2026Review
- Hydrogel-Flexible Electronics Integrated Platforms for Diabetic Wound Management.Materials (Basel, Switzerland) · 2026Review
- Advances in Surface Biofunctionalization and Intelligent Monitoring of Vascular Scaffolds.Research (Washington, D.C.) · 2026Review
- Automation of electrothermal cell sheet manipulator for seamless tissue assembly and handling.Biomedical microdevices · 2025Article
- Motion Artifacts Removal from Measured Arterial Pulse Signals at Rest: A Generalized SDOF-Model-Based Time-Frequency Method.Sensors (Basel, Switzerland) · 2025Article
- State-of-the-art wearable sensors for cardiovascular health: a review.NPJ cardiovascular health · 2025Review
- An Analytical Model of Motion Artifacts in a Measured Arterial Pulse Signal-Part I: Accelerometers and PPG Sensors.Sensors (Basel, Switzerland) · 2025Article
- Skin-Inspired Healthcare Electronics.Biomimetics (Basel, Switzerland) · 2025Review
- On-Skin Epidermal Electronics for Next-Generation Health Management.Nano-micro letters · 2025Review
- FromMaterials today. Bio · 2025Review
- Hydrogels in Cardiac Surgery: Versatile Platforms for Tissue Repair, Adhesion Prevention, and Localized Therapeutics.Gels (Basel, Switzerland) · 2025Review
- Regulation of partial endothelial-to-mesenchymal transition by circATXN1 in ischemic diseases.Nature communications · 2025Article
- Recent Achievements of Epicardial Patch Electronics Using Adhesive and Conductive Hydrogels.Gels (Basel, Switzerland) · 2025Review
- Advancements in Bio-Integrated Flexible Electronics for Hemodynamic Monitoring in Cardiovascular Healthcare.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cardiovascular diseases (CVDs) are one of the most urgent threats to humans worldwide, which are responsible for almost one-third of global mortality. Over the last decade, research on flexible electronics for monitoring and treatment of CVDs has attracted tremendous attention. In contrast to conventional medical instruments in hospitals that are usually bulky, hard to move, monofunctional, and time-consuming, flexible electronics are capable of continuous, noninvasive, real-time, and portable monitoring. Notable progress has been made in this emerging field, and thus a number of significant achievements and concomitant research prospects deserve attention for practical implementation. Here, we comprehensively review the latest progress of flexible electronics for CVDs, focusing on new functions provided by flexible electronics. First, the characteristics of CVDs and flexible electronics and the foundation of their combination are briefly reviewed. Then, four representative applications of flexible electronics for CVDs are elaborated: blood pressure (BP) monitoring, electrocardiogram (ECG) monitoring, echocardiogram monitoring, and direct epicardium monitoring. Their operational principles, progress, merits and demerits, and future efforts are discussed. Finally, the remaining challenges and opportunities for flexible electronics for cardiovascular healthcare are outlined.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.