ArticleArchives of academic emergency medicine2023
Comparing the Efficacy of Long Spinal Board, Sked Stretcher, and Vacuum Mattress in Cervical Spine Immobilization; a Method-Oriented Experimental Study.
Article in Archives of academic emergency medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 4 citations in OpenAlex.
- Design and application of a novel surgical transfer sheet: a randomized controlled trial.BMC nursing · 2025Article
- Can generative artificial intelligence provide accurate medical advice?: a case of ChatGPT versus Congress of Neurological Surgeons management of acute cervical spine and spinal cord injuries clinical guidelines.Asian spine journal · 2025Article
- Comparison of Video Laryngoscope (VL) and Intubating Laryngeal Mask Airway (I-LMA) for Endotracheal Intubation in a Manikin with Restricted Neck Motion.Archives of academic emergency medicine · 2025Article
- Traditional Spinal Immobilization versus Spinal Motion Restriction in Cervical Spine Movement; a Randomized Crossover Trial.Archives of academic emergency medicine · 2024Article
- Validity of Inertial Measurement Unit (IMU Sensor) for Measurement of Cervical Spine Motion, Compared with Eight Optoelectronic 3D Cameras Under Spinal Immobilization Devices.Medical devices (Auckland, N.Z.) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Inadequate spinal motion restriction in patients suffering from spinal injuries could lead to further neurological damage, ultimately worsening their prognosis. This study aimed to investigate the efficacy of long spinal boards (LSB), ske stretcher, and vacuum mattress for cervical spine immobilization during transportation of patients by measuring the angular motion of the cervical spine following lifting, transferring, and tilting. Methods: We conducted an experimental study using a box of three randomizations and crossover designs without a washout period effect for the long spinal board, sked stretcher, and vacuum mattress. We concealed the randomization with sequentially numbered, opaque, sealed envelopes (SNOSE). Kinematic data were collected using eight optoelectronic cameras at 200 Hz (BTS Bioengineering, Milan, Italy) in triangular planes (lateral bending, flexion-extension, and axial rotation) while performing all three motions (static lift-hold, transfer, and 90° tilt). Results: 12 cases (7 males and 5 females) with the mean age of 20 ± 3.03 (range: 18-28) years were studied. The three highest angular motions were observed in the axial rotation plane during patient's tilting under immobilization on all devices (Vacuum mattress having the highest value of 99.01±8.93, followed by the LSB at 89.89±34.35 and the sked stretcher at 86.30±7.73 degrees). During patient lifting, a higher angular motion was observed with vacuum mattress immobilization in flexion extension (Coefficient = 4.45; 95%CI: 0.46 - 8.45; p =0.029) and axial rotation (Coefficient = 3.70; 95%CI: 0.58 - 6.81; p =0.020) planes. During patient transfer, a higher angular motion was observed with sked stretcher in the flexion-extension plane (Coefficient = 2.98; 95%CI: 0.11 - 5.84; p = 0.042). During patient tilting to 90 degrees, a higher angular motion was observed with vacuum mattress immobilization in lateral bending (Coefficient = -4.08; 95%CI: -7.68 - -0.48; p = 0.026) for the vacuum mattress. Conclusion: Based on the finding of the present study, patients on the vacuum mattress experience significantly higher angular motion in flexion extension and axial rotation during lifting, as well as lateral bending during 90-degree tilting. In addition, patients on the sked stretcher showed significantly higher angular motion in flexion-extension during the transferring. However, the predictive margins for immobilization across all devices did not demonstrate clinically significant differences among the three immobilization devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.