Influence of ultrasound machine settings on quantitative measures derived from spatial frequency analysis of muscle tissue.

Scott K Crawford, Stephanie A Kliethermes, Bryan C Heiderscheit, Greg R Bashford

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Scott K CrawfordDepartment of Kinesiology, University of Wisconsin-Madison, 1300 University Ave, Madison, WI, 53706, USA. skcrawford2@wisc.edu.
Stephanie A KliethermesDepartment of Orthopedics & Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA.
Bryan C HeiderscheitDepartment of Orthopedics & Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA.
Greg R BashfordDepartment of Biological Systems Engineering, University of Nebraska, Lincoln, NE, USA.

Funding

University of Wisconsin Institute for Clinical and Translational ResearchUL1TR002373 · NCATS · UNIVERSITY OF WISCONSIN-MADISON · PI ELIZABETH S BURNSIDE, Allan R. Brasier · 2017 to 2026
$75.9M
NRSA Training CoreTL1TR002375 · NCATS · UNIVERSITY OF WISCONSIN-MADISON · PI Vivek Prabhakaran · 2017 to 2026
$8.4M
NCATS NIH HHS TL1 TR002375NCATS NIH HHS UL1 TR002373
6 · The paper itself

Abstract

backgroundUltrasound is a powerful tool for diagnostic purposes and provides insight into both normal and pathologic tissue structure. Spatial frequency analysis (SFA) methods characterize musculoskeletal tissue organization from ultrasound images. Both sonographers in clinical imaging and researchers may alter a minimized range of ultrasound settings to optimize image quality, and it is important to know how these small adjustments of these settings affect SFA parameters. The purpose of this study was to investigate the effects of making small adjustments in a typical default ultrasound machine setting on extracted spatial frequency parameters (peak spatial frequency radius (PSFR), Mmax, Mmax%, and Sum) in the biceps femoris muscle.

methodsLongitudinal B-mode images were collected from the biceps femoris muscle in 36 participants. The window depth, foci locations, and gain were systematically adjusted consistent with clinical imaging procedures for a total of 27 images per participant. Images were analyzed by identifying a region of interest (ROI) in the middle portion of the muscle belly in a template image and using a normalized two-dimensional cross-correlation technique between the template image and subsequent images. The ROI was analyzed in the frequency domain using conventional SFA methods. Separate linear mixed effects models were run for each extracted parameter.

resultsPSFR was affected by modifications in focus location only (p < 0.001) with differences noted between all locations. Mmax% was influenced by the interaction of gain and focus location (p < 0.001) but was also independently affected by increasing window depth (p < 0.001). Both Mmax and Sum parameters were sensitive to small changes in machine settings with the interaction of focus location and window depth (p < 0.001 for both parameters) as well as window depth and gain (p < 0.001 for both) influencing the extracted values.

conclusionsFrequently adjusted imaging settings influence some SFA statistics. PSFR and Mmax% appear to be most robust to small changes in image settings, making them best suited for comparison across individuals and between studies, which is appealing for the clinical utility of the SFA method.

Indexed as

Hamstring MusclesMusclesAllied Health PersonnelHumansLinear ModelsUltrasonographyHamstring musclesImagingMusculoskeletalSpatial frequencyUltrasonography

Identifiers

PMID37608370
PMCPMC10463672

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.