Evidence map›Paper›PMID 37606872›Full record

ArticleJournal of robotic surgery2023

Prospective Comparison of Two Robotically Navigated Pedicle Screw Instrumentation Techniques.

Fedan Avrumova, Frederik Abel, William D Zelenty, Samuel N Goldman, Darren R Lebl

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Fedan AvrumovaDepartment of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.ORCID http://orcid.org/0000-0003-3760-8776
Frederik AbelDepartment of Radiology, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.ORCID http://orcid.org/0000-0001-8988-6917
William D ZelentyDepartment of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.ORCID http://orcid.org/0000-0002-5864-3784
Samuel N GoldmanDepartment of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.ORCID http://orcid.org/0000-0003-2199-4318
Darren R LeblDepartment of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA. Research@leblspinemd.com.ORCID http://orcid.org/0000-0003-2890-5795
Hospital for Special Surgery · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to compare screw accuracy and incidence of skive between two robotically navigated instrumented techniques in posterior spine fusion surgery: manual anti-skive instrumentation with an anti-skive cannula (ASC) and the use of a navigated, high-speed drill (HSD). Over a 3-year period, consecutive patients are undergoing RNA posterior fusion surgery with either ASC (n = 53) or HSD (n = 63). Both groups met a value of approximately 292 screws in our analysis (296 ASC, 294 HSD), which was determined by a biostatistician at an academic institution. Screw accuracy and skive was analyzed using preoperative CT and intraoperative three-dimensional (3D) fluoroscopy. Among 590 planned robotically inserted pedicle screws (296 ASC, 294 HSD), 245 ASC screws (82.8%) and 283 HSD screws (96.3%) were successfully inserted (p < 0.05). Skive events occurred in 4/283 (1.4%) HSD screws and 15/245 (6.2%) ASC screws (p < 0.05). HSD screws showed better accuracy in the axial and sagittal planes, being closer to planned trajectories in all directions except cranial deviation (p < 0.05). Additionally, HSD had a significantly lower time per screw (1.9 ± 1.0 min) compared to ASC (3.2 ± 2.0 min, p < 0.001). No adverse clinical effects were observed. The HSD technique showed significant improvements in time and screw accuracy compared to ASC. Biplanar fluoroscopy and 3D imaging resulted in significantly lower radiation exposure and time compared to ASC. These significant findings in the HSD group may be attributed to the lower occurrence of malpositioned screws, leading to a decrease in the need for second authentication. This represents a notable iterative improvement of the RNA platform.

Indexed as

Pedicle ScrewsRobotic Surgical ProceduresSurgery, Computer-AssistedFluoroscopyHumansRNARNAAccuracyFusionPedicleRobotic-navigated assistanceSkive

Identifiers

PMID37606872
OpenAlexW4386045918

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.