Evidence map›Paper›PMID 37606841›Full record

ArticleAnnals of surgical oncology2023

Augmented Reality Navigation Plus Indocyanine Green Fluorescence Imaging Can Accurately Guide Laparoscopic Anatomical Segment 8 Resection.

Haisu Tao, Zhuangxiong Wang, Xiaojun Zeng, Haoyu Hu, Jiang Li, Jinyu Lin, Wenjun Lin, Chihua Fang, Jian Yang

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of surgical oncology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Haisu Tao *Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
Zhuangxiong Wang *Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
Xiaojun Zeng *Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
Haoyu HuDepartment of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
Jiang LiThe First Affiliated Hospital, College of Medicine, Shihezi University, Shihezi, China.
Jinyu LinDepartment of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
Wenjun LinDepartment of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
Chihua FangDepartment of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China. fangchihua@smu.edu.cn.
Jian YangDepartment of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China. yangjian486@126.com.ORCID http://orcid.org/0000-0003-4721-7744

Funding

Basic and Applied Basic Research Foundation of Guangdong Province 2021A1515011869China Postdoctoral Science Foundation 2022M721514National Natural Science Foundation of China 82272132President's Fund of Zhujiang Hospital yzjj2022qn31Regional Joint Fund of Guangdong (Guangdong-Hong Kong-Macao Research Team Project) 2021B1515130003the Science and Technology Plan Project of Guangdong Province 2021A1414020003
6 · The paper itself

Abstract

backgroundLaparoscopic anatomical Segment 8 (S8) resection is a highly challenging hepatectomy. Augmented reality navigation (ARN), which could be combined with indocyanine green (ICG) fluorescence imaging, has been applied in various complex liver resections and may also be applied in laparoscopic anatomical S8 resection. However, no study has explored how to apply ARN plus ICG fluorescence imaging (ARN-FI) in laparoscopic anatomical S8 resection, or explored its accuracy. PATIENTS AND

methodsThis study is a post hoc analysis that included 31 patients undergoing laparoscopic anatomical S8 resection from the clinical NaLLRFI trial, and the resected liver volume was measured in each patient. The perioperative parameters of safety and feasibility, as well as the accuracy analysis outcomes were compared.

resultsThere were 16 patients in the ARN-FI group and 15 patients underwent conventional laparoscopic hepatectomy without ARN or fluorescence imaging (non-ARN-FI group). There was no significant difference in baseline characteristics between the two groups. Compared with the non-ARN-FI group, the ARN-FI group had lower intraoperative bleeding (median 125 vs. 300 mL, P = 0.003). No significant difference was observed in other postoperative short-term outcomes. Accuracy analysis indicated that the actual resected liver volume (ARLV) in the ARN-FI group was more accurate.

conclusionsARN-FI was associated with less intraoperative bleeding and more accurate resection volume. These techniques may address existing challenges and provide rational guidance for laparoscopic anatomical S8 resection.

Indexed as

Augmented RealityHepatectomyIndocyanine GreenLaparoscopyLiver NeoplasmsOptical ImagingSurgery, Computer-AssistedAgedColoring AgentsFemaleFollow-Up StudiesHumansMaleMiddle AgedPrognosisColoring AgentsIndocyanine GreenAnatomical S8 resectionAugmented realityICG fluorescenceSurgical navigation

Identifiers

PMID37606841

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.