Evidence map›Paper›PMID 37605070›Full record

ArticleJournal of experimental orthopaedics2023

Difference in implant design affects midflexion rotational laxity in cruciate-retaining total knee arthroplasty: a computer navigation study.

Takashi Tsuda, Kazunori Hino, Tatsuhiko Kutsuna, Kunihiko Watamori, Tomofumi Kinoshita, Masaki Takao

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Takashi TsudaDepartment of Bone and Joint Surgery, Ehime University, Graduate School of Medicine, Shitsukawa, Toon City, Ehime, 791-0295, Japan.
Kazunori HinoDepartment of Joint Reconstruction, Ehime University, Graduate School of Medicine, Shitsukawa, Toon City, Ehime, 791-0295, Japan. ehukne@gmail.com.ORCID http://orcid.org/0000-0003-3601-639X
Tatsuhiko KutsunaDepartment of Bone and Joint Surgery, Ehime University, Graduate School of Medicine, Shitsukawa, Toon City, Ehime, 791-0295, Japan.
Kunihiko WatamoriDepartment of Joint Reconstruction, Ehime University, Graduate School of Medicine, Shitsukawa, Toon City, Ehime, 791-0295, Japan.
Tomofumi KinoshitaDepartment of Bone and Joint Surgery, Ehime University, Graduate School of Medicine, Shitsukawa, Toon City, Ehime, 791-0295, Japan.
Masaki TakaoDepartment of Bone and Joint Surgery, Ehime University, Graduate School of Medicine, Shitsukawa, Toon City, Ehime, 791-0295, Japan.
Ehime University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to compare midflexion rotational laxity between two different design concept models of cruciate-retaining total knee arthroplasty: symmetrical surface design of neutral joint line obliquity and asymmetrical surface design of varus joint line obliquity.

methodsSixty-three knees that underwent cruciate-retaining total knee arthroplasty were evaluated. Manual maximum passive rotational stress without acceleration was applied to the knees under navigation monitoring. Pre-operative and post-operative internal and external rotational angles were measured at 30°, 45°, 60°, and 90° knee flexion.

resultsThe post-operative internal rotational laxity was significantly increased compared with pre-operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 9.7° vs 11.1°, 10.6° vs 11.6°, 11.2° vs 12.9°, and 13.2° vs 14.9°; p = 0.01, 0.04, 0.001, and 0.008, respectively). The post-operative external rotational laxity was significantly decreased compared to pre-operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 10.8° vs 6.8°, 12.5° vs 9.4°, 12.8° vs 10.0°, and 11.3° vs 9.5°; p < 0.0001, < 0.0001, < 0.0001, and 0.0008, respectively). The post-operative total rotational laxity significantly decreased, compared with pre-operative levels, at 30° and 45° flexion among all subjects (mean 20.4° vs 17.9°, and 23.1° vs 21.1°; p = 0.002 and 0.04, respectively). The post-operative total rotational laxity was significantly smaller in asymmetrically designed total knee arthroplasty than in symmetrically designed total knee arthroplasty at 30°, 45°, and 60° flexion (mean 19.3° vs 15.8°, 22.8° vs 18.7°, and 24.4° vs 20.8°; p = 0.03, 0.03, and 0.02, respectively), whereas no significant difference was observed at 90° flexion.

conclusionCompared to symmetrical surface design, asymmetrical surface design resulted in lower rotational laxity at the midflexion range in cruciate-retaining total knee arthroplasty. LEVEL OF EVIDENCE: III.

Indexed as

Cruciate-retainingDesign of implantsMidflexion laxityNavigation systemRotational laxityTotal knee arthroplasty

Identifiers

PMID37605070
PMCPMC10441849
OpenAlexW4386022326

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.