Spatiotemporal denoising of low-dose cardiac CT image sequences using RecycleGAN.

Shiwei Zhou, Jinyu Yang, Krishnateja Konduri, Junzhou Huang, Lifeng Yu, Mingwu Jin

Abstract read
In one paragraph

Article in Biomedical physics & engineering express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shiwei ZhouDepartment of Physics, University of Texas at Arlington, Arlington, TX, United States of America.ORCID 0000-0003-3984-8917
Jinyu YangDepartment of Computer Science and Engineering, University of Texas at Arlington, Arlington, TX, United States of America.
Krishnateja KonduriDepartment of Bioengineering, University of Texas at Arlington, Arlington, TX, United States of America.
Junzhou HuangDepartment of Computer Science and Engineering, University of Texas at Arlington, Arlington, TX, United States of America.
Lifeng YuDepartment of Radiology, Mayo Clinic, Rochester, MN, United States of America.
Mingwu JinDepartment of Physics, University of Texas at Arlington, Arlington, TX, United States of America.ORCID 0000-0003-3987-2896

Funding

Attenuation correction strategies for myocardial perfusion imaging using dual-gated SPECTR15HL150708 · NHLBI · UNIVERSITY OF TEXAS ARLINGTON · PI JIN, MINGWU · 2020 to 2020
$472k
NHLBI NIH HHS R15 HL150708
6 · The paper itself

Abstract

Electrocardiogram (ECG)-gated multi-phase computed tomography angiography (MP-CTA) is frequently used for diagnosis of coronary artery disease. Radiation dose may become a potential concern as the scan needs to cover a wide range of cardiac phases during a heart cycle. A common method to reduce radiation is to limit the full-dose acquisition to a predefined range of phases while reducing the radiation dose for the rest. Our goal in this study is to develop a spatiotemporal deep learning method to enhance the quality of low-dose CTA images at phases acquired at reduced radiation dose. Recently, we demonstrated that a deep learning method, Cycle-Consistent generative adversarial networks (CycleGAN), could effectively denoise low-dose CT images through spatial image translation without labeled image pairs in both low-dose and full-dose image domains. As CycleGAN does not utilize the temporal information in its denoising mechanism, we propose to use RecycleGAN, which could translate a series of images ordered in time from the low-dose domain to the full-dose domain through an additional recurrent network. To evaluate RecycleGAN, we use the XCAT phantom program, a highly realistic simulation tool based on real patient data, to generate MP-CTA image sequences for 18 patients (14 for training, 2 for validation and 2 for test). Our simulation results show that RecycleGAN can achieve better denoising performance than CycleGAN based on both visual inspection and quantitative metrics. We further demonstrate the superior denoising performance of RecycleGAN using clinical MP-CTA images from 50 patients.

Indexed as

Computed Tomography AngiographyTomography, X-Ray ComputedAngiographyBenchmarkingHeartHumansCycleGANdenoisingmulti-phase CT angiography (MP-CTA)RecycleGAN

Identifiers

PMID37604139
PMCPMC10593187