ArticleIEEE transactions on medical imaging2024

Non-Isocentric Geometry for Next-Generation Tomosynthesis With Super-Resolution.

Raymond J Acciavatti, Chloe J Choi, Trevor L Vent, Bruno Barufaldi, Eric A Cohen, E Paul Wileyto, Andrew D A Maidment

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Raymond J Acciavatti
Chloe J Choi
Trevor L Vent
Bruno Barufaldi
Eric A Cohen
E Paul Wileyto
Andrew D A Maidment

Funding

UNIVERSITY OF PENNSYLVANIA CAN CTR SUPPORT GRANTP30CA016520 · NCI · UNIVERSITY OF PENNSYLVANIA · PI SHELLEY L BERGER · 1985 to 2026
$222.3M
High Performance, Quantitative Breast PET Scanner Integrated With TomosynthesisR01CA196528 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ANDREW DOUGLAS ARNOLD MAIDMENT, Suleman Surti · 2016 to 2026
$5.9M
Training Program in Biomedical Imaging and Information SciencesT32EB009384 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI GEE, JAMES C, IVES, ZACHARY · 2009 to 2023
$4.0M
Next-Generation Tomosynthesis Pilot StudyR37CA273959 · NCI · UNIVERSITY OF PENNSYLVANIA · PI Raymond Joseph Acciavatti · 2022 to 2026
$1.8M
NCI NIH HHS P30 CA016520NCI NIH HHS R01 CA196528NCI NIH HHS R37 CA273959NIBIB NIH HHS T32 EB009384
6 · The paper itself

Abstract

Our lab at the University of Pennsylvania (UPenn) is investigating novel designs for digital breast tomosynthesis. We built a next-generation tomosynthesis system with a non-isocentric geometry (superior-to-inferior detector motion). This paper examines four metrics of image quality affected by this design. First, aliasing was analyzed in reconstructions prepared with smaller pixelation than the detector. Aliasing was assessed with a theoretical model of r -factor, a metric calculating amplitudes of alias signal relative to input signal in the Fourier transform of the reconstruction of a sinusoidal object. Aliasing was also assessed experimentally with a bar pattern (illustrating spatial variations in aliasing) and 360°-star pattern (illustrating directional anisotropies in aliasing). Second, the point spread function (PSF) was modeled in the direction perpendicular to the detector to assess out-of-plane blurring. Third, power spectra were analyzed in an anthropomorphic phantom developed by UPenn and manufactured by Computerized Imaging Reference Systems (CIRS), Inc. (Norfolk, VA). Finally, calcifications were analyzed in the CIRS Model 020 BR3D Breast Imaging Phantom in terms of signal-to-noise ratio (SNR); i.e., mean calcification signal relative to background-tissue noise. Image quality was generally superior in the non-isocentric geometry: Aliasing artifacts were suppressed in both theoretical and experimental reconstructions prepared with smaller pixelation than the detector. PSF width was also reduced at most positions. Anatomic noise was reduced. Finally, SNR in calcification detection was improved. (A potential trade-off of smaller-pixel reconstructions was reduced SNR; however, SNR was still improved by the detector-motion acquisition.) In conclusion, the non-isocentric geometry improved image quality in several ways.

Indexed as

CalcinosisImage Processing, Computer-AssistedAlgorithmsBreastComputer SimulationHumansMammographyModels, TheoreticalPhantoms, Imaging

Identifiers

PMID37603482
PMCPMC10764004