ArticleMedical physics2023

Exploration of the pulse pileup effects in a clinical CdTe-based photon-counting computed tomography.

Mridul Bhattarai, Steve Bache, Ehsan Abadi, Ehsan Samei

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Mridul BhattaraiMedical Physics Graduate Program, Duke University, Durham, North Carolina, USA.
Steve BacheClinical Imaging Physics Group - Duke University Health System, Durham, North Carolina, USA.
Ehsan AbadiMedical Physics Graduate Program, Duke University, Durham, North Carolina, USA.
Ehsan SameiMedical Physics Graduate Program, Duke University, Durham, North Carolina, USA.
Duke University · USDuke University Health System · US

Funding

TR&D Project 3: Virtual ReadersP41EB028744 · NIBIB · DUKE UNIVERSITY · PI Ehsan Samei · 2021 to 2026
$7.8M
Simulation Tools for Dynamic CTR01EB001838 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SAMEI, EHSAN, SEGARS, WILLIAM P · 2005 to 2023
$6.9M
Accuracy and Precision in CT Quantification of COPD Through Virtual Imaging TrialsR01HL155293 · NHLBI · DUKE UNIVERSITY · PI ABADI, EHSAN · 2021 to 2025
$2.2M
NHLBI NIH HHS R01 HL155293NIBIB NIH HHS P41 EB028744NIBIB NIH HHS R01 EB001838NIH HHS P41EB028744NIH HHS R01EB001838NIH HHS R01HL155293
6 · The paper itself

Abstract

backgroundHigh tube current generates a high flux of x-rays to photon counting detectors (PCDs) that can potentially result in the piling up of pulses formed by concurrent photons, which can cause count loss and energy resolution degradation. PURPOSE: To evaluate the performance of clinical photon-counting CT (PCCT) systems in high flux, potentially influenced by pulse pileup effects, in terms of task-generic image quality metrics.

methodsA clinical phantom was scanned on a commercial PCCT scanner (NAEOTOM Alpha, Siemens) at 120 kV under fourteen different tube current levels (40-1000 mA) with a rotation time of 0.25 s and a pitch of 1. The dose levels corresponded to CTDI

resultsThe 50% cut-off frequency of TTF (f

conclusionsIncreasing tube currents did not affect the spatial resolution, but slightly affected the CT number and noise measurements of the clinical PCCT system. However, the effects were only considerable at clinically irrelevant tube currents used on a small 20-cm phantom. In general clinical practices, automatic exposure control techniques are used to decrease the variation of flux on the detector, which alleviates the chances of detector saturation due to high count rates. The observed effects could be due to pulse pileup, signal-dependent filtration of the system, or nonlinearities in the reconstruction algorithm. In conclusion, either the deadtime of the detector used in the photon-counting CT system is shorter such that count losses due to pulse pileup are negligible, or pulse pileup has inconsiderable effects on the image quality of clinical photon-counting CT systems in routine clinical practice due to possible corrections applied on the system.

Indexed as

Cadmium CompoundsQuantum DotsPhantoms, ImagingPhotonsTelluriumTomography, X-Ray ComputedCadmium Compoundscadmium tellurideTelluriumACR phantomcomputed tomographycontrast-to-noise ratio (CNR)CT numberfluxmodulation transfer function (MTF)noise power spectrum (NPS)photon counting CTPoisson statisticspulse pileup

Identifiers

PMID37602816
PMCPMC10840699
OpenAlexW4386019304

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.