Evidence map›Paper›PMID 37601498›Full record

ArticleSaudi journal of anaesthesia

Intraoperative electromyographic monitoring in children using a novel pediatric sensor.

Sidhant Kalsotra, Julie Rice-Weimer, Joseph D Tobias

Open access · diamondAbstract read
In one paragraph

Article in Saudi journal of anaesthesia. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
4.8field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 14 citations in OpenAlex.

  1. Observational
  2. Error Traps in Pediatric Neuromuscular Block.Paediatric anaesthesia · 2026
    Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Sidhant KalsotraDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH, USA.
Julie Rice-WeimerDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH, USA.
Joseph D TobiasDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH, USA.
Nationwide Children's Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Train-of-four (TOF) monitoring is essential in optimizing perioperative outcomes as a means to assess the depth of neuromuscular blockade and confirm recovery following the administration of neuromuscular blocking agents (NMBAs). Quantitative TOF monitoring has been limited in infants and children primarily due to lack of effective equipment. The current study evaluates a novel electromyography (EMG)-based TOF monitor with a recently developed pediatric-sized self-adhesive sensor in infants and children. Methods: Consented pediatric patients undergoing inpatient surgery requiring the administration of NMBAs were enrolled. The EMG electrode was placed along the ulnar nerve on the volar aspect of the distal forearm. The muscle action potentials from the adductor pollicis muscle were recorded throughout surgery at 20-second intervals. Data from the monitor's built-in memory card were later retrieved and analyzed. Results: The final study cohort included 51 patients who ranged in age from 0.2 to 7.9 years and in weight from 4.2 to 36.0 kilograms. Thirty patients weighed less than 15 kgs. Supramaximal stimulus current intensity (mA) at a pulse width of 200 μsec was 30 mA in 8%; 40 mA in 29%; 50 mA in 16%; and 60 mA in 20% of the patients. Supramaximal stimulus current intensity (mA) at a pulse width of 300 μsec was 50 mA in 4%; 60 mA in 24%. The muscle action potential baseline amplitude was 8.7 ± 3.3 mV and recovered to 7.2 ± 3.7 mV after antagonism of neuromuscular blockade. The average baseline TOF ratio was 100 ± 3% and recovered to 98 ± 7% after antagonism of neuromuscular blockade. No technical issues were noted with application of the sensor or subsequent use of the monitor. Conclusion: Neuromuscular monitoring can be performed intraoperatively in pediatric patients who are less than 8 years of age using a novel commercially available EMG-based monitor with a recently developed pediatric sensor. The novel sensor allows use of an EMG-based monitor in infants and children in whom acceleromyography or subjective (visual) observation of the TOF response may not be feasible. Automatic detection of neuromuscular stimulating parameters (supramaximal current intensity level, baseline amplitude of the muscle action potential) was feasible in pediatric patients of all sizes including those weighing less than 15 kilograms or when there was limited access to the extremity being monitored.

Indexed as

Laparoscopic surgeryneuromuscular blockadeneuromuscular blocking agentstrain-of-four monitoring

Identifiers

PMID37601498
PMCPMC10435795
OpenAlexW4382247332

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.