ArticleFrontiers in cardiovascular medicine2023
One-year clinical outcomes following Edwards INSPIRIS RESILIA aortic valve implantation in 487 young patients with severe aortic stenosis: a single-center experience.
Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.
- Early and late clinical outcomes and cost-effectiveness of aortic valve replacement using the Inspiris Resilia bioprosthesis : A systematic review and meta-analysis.Journal of cardiothoracic surgery · 2025Pooled it
- Three-Year Outcomes After Surgical Aortic Valve Replacement With a Bioprosthetic Valve from the Multi-Centre IMPACT Registry.Interdisciplinary cardiovascular and thoracic surgery · 2026Article
- Prosthesis-Patient Mismatch Following Aortic Valve Replacement-A Comprehensive Review.Journal of clinical medicine · 2025Review
- Article
- Mid-Term Outcomes After Aortic Valve Replacement in Patients Under 70: A Comparative Study of INSPIRIS RESILIA Versus PERIMOUNT MAGNA EASE Bioprostheses.Interdisciplinary cardiovascular and thoracic surgery · 2025Article
- Long-term Mechanical Durability of Inspiris RESILIA Surgical Aortic Valves.Annals of thoracic surgery short reports · 2025Article
- Contemporary Management of the Aortic Valve-Narrative Review of an Evolving Landscape.Journal of clinical medicine · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: The use of an aortic bioprosthesis is on the rise in younger patients with severe aortic stenosis despite the risk of accelerated structural valve degeneration (SVD). In the search for an optimal valve substitute that would not be prone to SVD, the INSPIRIS bioprosthesis represents a promising solution to lowering the risk of SVD. Here, we report the 1-year outcomes of the INSPIRIS RESILIA aortic bioprosthesis in a population of young patients who underwent aortic valve replacement. Methods: In this prospective single-center study, we included all consecutive patients receiving INSPIRIS RESILIA bioprosthesis between June 2017 and July 2021. Patients with isolated severe aortic regurgitation were excluded. Clinical assessment and transthoracic echocardiography were performed preoperatively and at 1 year post-operatively. The primary outcome was overall mortality at one year. Results: A total of 487 patients were included. The mean age was 58.2 ± 11.5 years, 75.2% were men. Most of the interventions were elective, with a mean EuroSCORE II of 4.8 ± 7.9. The valve annulus size in most cases was either 23 mm or 25 mm. Overall mortality at 1-year was 4.1%. At 1-year, 7 patients (1.4%) had a stroke, 4 patients (0.8%) had a myocardial infarction, and 20 patients (4.1%) were hospitalized for congestive heart failure. The Kaplan-Meier estimated survival rates and survival without major adverse cardiac events at 1-year were 96.4% and 96.7%, respectively. At 1-year follow-up, 10 patients (2.1%) had endocarditis and 1 patient (0.2%) had partial prosthetic thrombosis. Pacemaker implantation at 1-year post-operative was necessary in 27 patients (5.5%). Severe patient prosthesis mismatch and severe intra valvular regurgitation were 1.2% and 0.6%, respectively. The Kaplan-Meier estimated survival rates at 1-year of no infective endocarditis preoperative and infective endocarditis preoperative were 97.9 ± 0.7% and 89.5 ± 3.3%, respectively ( Conclusion: This is the largest single-center descriptive study of the 1-year outcomes after INSPIRIS RESILIA bioprosthesis implantation. The EDWARDS INSPIRIS RESILIA bioprosthesis provides encouraging clinical outcomes with an excellent 1- year survival rates and good hemodynamic performance. Long-term studies are mandatory to assess valve durability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.