Evidence map›Paper›PMID 37598779›Full record

ArticleThe Journal of arthroplasty2024

Effect of Femoral Head Material, Surgeon Experience, and Assembly Technique on Simulated Head-Neck Total Hip Arthroplasty Impaction Forces.

Michael Godoy, Kirsten Sipek, Jonathan A Gustafson, Catherine Yuh, Brett R Levine, Robin Pourzal, Hannah J Lundberg

Abstract read
In one paragraph

Article in The Journal of arthroplasty, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Michael GodoyDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.
Kirsten SipekDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.
Jonathan A GustafsonDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.
Catherine YuhDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.
Brett R LevineDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.
Robin PourzalDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.
Hannah J LundbergDepartment of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.

Funding

Corrosion Induced Hip Implant Failure: Synergistic Interactions of Patient, Material, Design, and Surgical FactorsR01AR070181 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI LUNDBERG, HANNAH JEAN, MATHEW, MATHEW THOPPIL · 2016 to 2020
$2.3M
NIAMS NIH HHS R01 AR070181
6 · The paper itself

Abstract

backgroundThere is no standard method for assembling the femoral head onto the femoral stem during total hip arthroplasty (THA). This study aimed to measure and record dynamic 3-dimensional (3D) THA head-neck assembly loads from residents, fellows, and attending surgeons, for metal and ceramic femoral heads.

methodsAn instrumented apparatus measured dynamic 3D forces applied through the femoral stem taper in vitro for 31 surgeons (11 attendings, 14 residents, 6 fellows) using their preferred technique (ie, number of hits or mallet strikes). Outcome variables included peak axial force, peak resultant force, impulse of the resultant force, loading rate of the resultant force, and off-axis angle. They were compared between femoral head material, surgeon experience level, and the number of hits per trial.

resultsAverage peak axial force was 6.92 ± 2.11kN for all surgeons. No significant differences were found between femoral head material. Attendings applied forces more "on-axis" as compared to both residents and fellows. Nine surgeons assembled the head with 1 hit, 3 with 2 hits, 14 with 3 hits, 2 with 4 hits, and 3 with ≥5 hits. The first hit of multihit trials was significantly lower than single-hit trials for all outcome measures except the off-axis angle. The last hit of multihit trials had a significantly lower impulse of resultant force than single-hit trials.

conclusionDifferences in applied 3D force-time curve dynamic characteristics were found between surgeon experience level and single and multihit trials. No significant differences were found between femoral head material.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisSurgeonsFemur HeadHumansProsthesis DesignProsthesis Failureassembly techniquefemoral head materialhead-neck modularitysurgeon experiencetotal hip arthroplasty

Identifiers

PMID37598779
PMCPMC10850914

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.