Evidence map›Paper›PMID 37598755›Full record

ArticleIndian pacing and electrophysiology journal

Conduction system pacing in difficult cardiac anatomies: Systematic approach with the 3D electroanatomic mapping guide.

Lina Marcantoni, Marco Centioni, Gianni Pastore, Federico Aneris, Enrico Baracca, Francesco Zanon

Open access · goldAbstract read
In one paragraph

Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Lina MarcantoniArrhythmia and Electrophysiological Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy.
Marco CentioniArrhythmia and Electrophysiological Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy.
Gianni PastoreArrhythmia and Electrophysiological Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy.
Federico AnerisArrhythmia and Electrophysiological Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy.
Enrico BaraccaArrhythmia and Electrophysiological Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy.
Francesco ZanonArrhythmia and Electrophysiological Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy. Electronic address: francesco.zanon@aulss5.veneto.it.
Ospedale Santa Maria della Misericordia di Rovigo · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionRestoring physiological cardiac electrical activity in patients with conduction disease can be crucial for the survival and quality of life. Conduction system pacing (CSP) is a valuable option, although it is limited by technical challenges in difficult anatomies. 3D electroanatomical mapping (3D-EAM) can support CSP ensuring high electro-anatomical precision and low fluoroscopy.

objectivesWe evaluated the feasibility and effectiveness of a systematic 3D-EAM use to guide CSP in difficult anatomical scenarios (highly dilated atria, congenital cardiomyopathies, failed biventricular implants (BiV) and pacing-induced cardiomyopathy (PICM)).

methodsForty-three consecutive patients (27 males, 75 ± 10 years old) with standard pacing indications and difficult anatomical scenarios were included. The right atrium, His cloud, and atrio-ventricular septum were reconstructed by 3D-EAM. The His bundle (HB) was the initial target, while left bundle branch area pacing (LBBAP) was aimed at in case of unsatisfactory parameters, sub-optimally paced QRS, or impossibility of reaching the HB.

resultsCSP was successful in 37 (86%) patients (15 HBP; 22 LBBAP). Mean mapping, fluoroscopy, and procedural times were 18 ± 7 min, 7 ± 5 min, 98 ± 47 min, respectively. The mean pacing threshold, R wave sensing, and pacing impedance of CSP lead were 1.2 ± 0.5V@0.5ms, 11.4 ± 6.2 mV, 736 ± 306 Ω, respectively. Baseline and paced QRS were 139 ± 38 ms and 114 ± 23 ms, respectively. No procedural complications were observed.

conclusions3D-EAM allowed the accurate definition of the His cloud and high ventricular septum and effectively guided CSP. It facilitated CSP in complex anatomies, with a procedural success rate of 86%. The results were satisfactory and reproducible, with acceptable fluoroscopy and procedural times.