Evidence map›Paper›PMID 37598253›Full record

ArticleCommunications medicine2023

Noninvasive and reliable automated detection of spreading depolarization in severe traumatic brain injury using scalp EEG.

Alireza Chamanzar, Jonathan Elmer, Lori Shutter, Jed Hartings, Pulkit Grover

Open access · goldAbstract read
In one paragraph

Article in Communications medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Brain health: A concern for anaesthesiologists and intensivists.European journal of anaesthesiology and intensive care · 2024
    Review
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Alireza ChamanzarElectrical and Computer Engineering Department, Carnegie Mellon University, Pittsburgh, PA, USA. achamanz@andrew.cmu.edu.ORCID http://orcid.org/0000-0001-6319-7486
Jonathan ElmerDepartments of Emergency Medicine, Critical Care Medicine and Neurology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.
Lori ShutterDepartment of Critical Care Medicine, Neurology and Neurosurgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.ORCID http://orcid.org/0000-0002-1390-0628
Jed HartingsDepartment of Neurosurgery, University of Cincinnati, Cincinnati, OH, USA.
Pulkit GroverElectrical and Computer Engineering Department, Carnegie Mellon University, Pittsburgh, PA, USA. pgrover@andrew.cmu.edu.ORCID http://orcid.org/0000-0001-7651-7776
Carnegie Mellon University · USUniversity of Pittsburgh · USUniversity of Cincinnati · US

Funding

Quantitative electroencephalography after cardiac arrestK23NS097629 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI ELMER, JONATHAN · 2017 to 2021
$945k
NINDS NIH HHS K23 NS097629
6 · The paper itself

Abstract

backgroundSpreading depolarizations (SDs) are a biomarker and a potentially treatable mechanism of worsening brain injury after traumatic brain injury (TBI). Noninvasive detection of SDs could transform critical care for brain injury patients but has remained elusive. Current methods to detect SDs are based on invasive intracranial recordings with limited spatial coverage. In this study, we establish the feasibility of automated SD detection through noninvasive scalp electroencephalography (EEG) for patients with severe TBI.

methodsBuilding on our recent WAVEFRONT algorithm, we designed an automated SD detection method. This algorithm, with learnable parameters and improved velocity estimation, extracts and tracks propagating power depressions using low-density EEG. The dataset for testing our algorithm contains 700 total SDs in 12 severe TBI patients who underwent decompressive hemicraniectomy (DHC), labeled using ground-truth intracranial EEG recordings. We utilize simultaneously recorded, continuous, low-density (19 electrodes) scalp EEG signals, to quantify the detection accuracy of WAVEFRONT in terms of true positive rate (TPR), false positive rate (FPR), as well as the accuracy of estimating SD frequency.

resultsWAVEFRONT achieves the best average validation accuracy using Delta band EEG: 74% TPR with less than 1.5% FPR. Further, preliminary evidence suggests WAVEFRONT can estimate how frequently SDs may occur.

conclusionsWe establish the feasibility, and quantify the performance, of noninvasive SD detection after severe TBI using an automated algorithm. The algorithm, WAVEFRONT, can also potentially be used for diagnosis, monitoring, and tailoring treatments for worsening brain injury. Extension of these results to patients with intact skulls requires further study.

Identifiers

PMID37598253
PMCPMC10439895
OpenAlexW4386001101

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.