ArticleBMC musculoskeletal disorders2023

Accuracy and reproducibility analysis of different reference axes for femoral prosthesis rotation alignment in TKA based on 3D CT femoral model.

Kun Liu, Xuande Liu, Yujun Guan, Haotong Ma, Donglin Fu, Zongqing Fan

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kun Liu *Fuyang People's Hospital, Anhui Medical University, NO.501 Sanqing Road, Yingzhou District, Fuyang, 236000, Anhui Province, China.
Xuande Liu *China Railway Fuyang Hospital, Fuyang, 236000, Anhui Province, China.
Yujun GuanFuyang People's Hospital, Anhui Medical University, NO.501 Sanqing Road, Yingzhou District, Fuyang, 236000, Anhui Province, China.
Haotong MaFuyang People's Hospital, Anhui Medical University, NO.501 Sanqing Road, Yingzhou District, Fuyang, 236000, Anhui Province, China.
Donglin FuFuyang People's Hospital, Anhui Medical University, NO.501 Sanqing Road, Yingzhou District, Fuyang, 236000, Anhui Province, China. fdl8732@163.com.
Zongqing FanFuyang People's Hospital, Anhui Medical University, NO.501 Sanqing Road, Yingzhou District, Fuyang, 236000, Anhui Province, China. Fanzongqing2007@163.com.

Funding

Natural Science Project of Bengbu Medical College 2022byzd171
6 · The paper itself

Abstract

backgroundThere are many reference axes to determine the rotational positioning of the femoral prosthesis in total knee arthroplasty (TKA), mainly including the surgical transepicondylar axis (sTEA), anatomical transepicondylar axis (aTEA), Whiteside line, and the posterior condylar line (PCL), etc., but there is still no definite conclusion on which is the most accurate reference axis.

objectiveTo explore the reproducibility of each reference axis of femoral external osteotomy based on the 3D CT femoral model, compare the deviation of the simulated femoral prosthesis rotation alignment, positioned based on each reference axis, with the gold standard sTEA, and analyze the accuracy of each reference axis.

methodsThe imaging data of 120 patients with knee osteoarthritis who underwent a 3D CT examination of the knee in our hospital from June 2018 to December 2021 were retrospectively collected. The 3D model of the femur was established by Mimics software. The line relative to PCL externally rotated 3° (PCL + 3°), aTEA, and the vertical line of the Whiteside line were constructed and compared with the gold standard sTEA. Intra-observer, as well as inter-observer reproducibility analysis, was performed by the intra-group correlation coefficient (ICC) and Bland-Altman method.

resultsThe angle ∠WS, between the vertical line of Whiteside and sTEA, was 2.54 ± 2.30°, with an outlier of 54.2%; the angle ∠aTEA, between aTEA and sTEA, was 4.21 ± 1.01°, with an outlier of 99.1%; the angle ∠PCL, between PCL + 3° external rotation and sTEA, was 0.50 ± 1.06°, with the highest accuracy and an outlier of 5.8%, and the differences among all three were statistically significant, P < 0.05. The intra-observer ICC values of ∠WS, ∠aTEA, and ∠PCL were 0.975 (0.964-0.982), 0.926 (0.896-0.948), and 0.924(0.892,0.946), respectively, and the reproducibility levels were excellent; the inter-observer ICC values of ∠WS, ∠aTEA, and ∠PCL were 0.968(0.955-0.978), 0.906 (0.868-0.934) and 0.970 (0.957,0.979), respectively, with excellent reproducibility levels; Bland-Altman plots suggested that the scatter points of intra-observer and inter-observer measurement differences more than 95% were within the limits of agreement.

conclusionThe reference axis for locating the distal femoral external rotation osteotomy based on the 3D CT femoral model has good reproducibility. The PCL is easy to operate, has the highest precision, and the lowest outliers among the reference axes is therefore recommended.

Indexed as

Arthroplasty, Replacement, KneeArtificial LimbsFemurHumansReproducibility of ResultsRetrospective StudiesTomography, X-Ray ComputedFemoral prosthesis rotationPosterior condylar anglePrecisionReproducibilityThree-dimensional CT

Identifiers

PMID37596664
PMCPMC10439596