Evidence map›Paper›PMID 37596563›Full record

ArticleBMC medical imaging2023

Fully automated film mounting in dental radiography: a deep learning model.

Yu-Chun Lin, Meng-Chi Chen, Cheng-Hsueh Chen, Mu-Hsiung Chen, Kang-Yi Liu, Cheng-Chun Chang

Abstract read
In one paragraph

Article in BMC medical imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yu-Chun LinDepartment of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan.
Meng-Chi ChenDepartment of Dentistry, Chang Gung Memorial Hospital at Taipei, Taipei, Taiwan.
Cheng-Hsueh ChenDepartment of Dentistry, National Taiwan University Hospital, Hsin-Chu Branch, Hsin-Chu, Taiwan.
Mu-Hsiung ChenDepartment of Dentistry, National Taiwan University Hospital, Taipei, Taiwan.
Kang-Yi LiuDepartment of Electrical Engineering, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd, Taipei, 10608, Taiwan.
Cheng-Chun ChangDepartment of Electrical Engineering, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd, Taipei, 10608, Taiwan. ccchang@mail.ntut.edu.tw.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDental film mounting is an essential but time-consuming task in dental radiography, with manual methods often prone to errors. This study aims to develop a deep learning (DL) model for accurate automated classification and mounting of both intraoral and extraoral dental radiography.

methodThe present study employed a total of 22,334 intraoral images and 1,035 extraoral images to train the model. The performance of the model was tested on an independent internal dataset and two external datasets from different institutes. Images were categorized into 32 tooth areas. The VGG-16, ResNet-18, and ResNet-101 architectures were used for pretraining, with the ResNet-101 ultimately being chosen as the final trained model. The model's performance was evaluated using metrics of accuracy, precision, recall, and F1 score. Additionally, we evaluated the influence of misalignment on the model's accuracy and time efficiency.

resultsThe ResNet-101 model outperformed VGG-16 and ResNet-18 models, achieving the highest accuracy of 0.976, precision of 0.969, recall of 0.984, and F1-score of 0.977 (p < 0.05). For intraoral images, the overall accuracy remained consistent across both internal and external datasets, ranging from 0.963 to 0.972, without significant differences (p = 0.348). For extraoral images, the accuracy consistently achieved the highest value of 1 across all institutes. The model's accuracy decreased as the tilt angle of the X-ray film increased. The model achieved the highest accuracy of 0.981 with correctly aligned films, while the lowest accuracy of 0.937 was observed for films exhibiting severe misalignment of ± 15° (p < 0.001). The average time required for the tasks of image rotation and classification for each image was 0.17 s, which was significantly faster than that of the manual process, which required 1.2 s (p < 0.001).

conclusionThis study demonstrated the potential of DL-based models in automating dental film mounting with high accuracy and efficiency. The proper alignment of X-ray films is crucial for accurate classification by the model.

Indexed as

Deep LearningHumansRadiography, DentalDeep learningDentalRadiography

Identifiers

PMID37596563
PMCPMC10439602

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.