Evidence map›Paper›PMID 37596379›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

Endoscopic measurement of the size of gastrointestinal polyps using an electromagnetic tracking system and computer vision-based algorithm.

Nazanin Safavian, Simon K C Toh, Martino Pani, Raymond Lee

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Nazanin SafavianFaculty of Technology, University of Portsmouth, Portsmouth, UK.
Simon K C TohDepartment of Upper GI Surgery, Portsmouth Hospital University NHS Trust, Queen Alexandra Hospital, Portsmouth, UK.
Martino PaniFaculty of Technology, University of Portsmouth, Portsmouth, UK.
Raymond LeeFaculty of Technology, University of Portsmouth, Portsmouth, UK. Raymond.lee@port.ac.uk.ORCID http://orcid.org/0000-0003-3580-5661
University of Portsmouth · GBQueen Alexandra Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePolyp size is an important factor that may influence diagnosis and clinical management decision, but estimation by visual inspection during endoscopy is often difficult and subject to error. The purpose of this study is to develop a quantitative approach that enables an accurate and objective measurement of polyp size and to study the feasibility of the method.

methodsWe attempted to estimate polyp size and location relative to the gastro-oesophageal junction by integrating data from an electromagnetic tracking sensor and endoscopic images. This method is based on estimation of the three-dimensional coordinates of the borders of the polyp by combining the endoscope camera position and the corresponding points along the polyp border in endoscopic images using a computer vision-based algorithm. We evaluated the proposed method using a simulated upper gastrointestinal endoscopy model.

resultsThe difference between the mean of ten measurements of one artificial polyp and its actual size (10 mm in diameter) was 0.86 mm. Similarly, the difference between the mean of ten measurements of the polyp distance from the gastroesophageal junction and its actual distance (~ 22 cm) was 1.28 mm. Our results show that the changes in camera positions in which the images were taken and the quality of the polyp segmentation have the most impact on the accuracy of polyp size estimation.

conclusionThis study demonstrated an innovative approach to endoscopic measurements using motion tracking technologies and computer vision and demonstrated its accuracy in determining the size and location of the polyp. The observed magnitude of error is clinically acceptable, and the measurements are available immediately after the images captured. To enhance accuracy, it is recommended to avoid identical images and instead utilise control wheels on the endoscope for capturing different views. Future work should further evaluate this innovative method during clinical endoscopic procedures.

Indexed as

Colonic PolypsGastrointestinal NeoplasmsAlgorithmsColonoscopyEndoscopesEndoscopy, GastrointestinalHumansMotionElectromagnetic tracking systemEndoscopyPolypSize estimation

Identifiers

PMID37596379
PMCPMC10838828
OpenAlexW4385970471

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.