Evidence map›Paper›PMID 37592020›Full record

Observational studyCardiovascular and interventional radiology2023

Prospective, Multicenter, Observational Study to Evaluate a Cell-Impermeable Endoprosthesis for Treatment of Stenosis or Occlusion within the Dialysis Outflow Circuit of an Arteriovenous (AV) Fistula or AV Graft (The WRAP Registry).

Dheeraj K Rajan, Panagiotis M Kitrou

Erratum issued Registry-linked trialOpen access · hybridAbstract readObservational StudyMulticenter Study
In one paragraph

Observational study in Cardiovascular and interventional radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT05062291 (Prospective, Multicenter, Observational Study to Evaluate the Merit WRAPSODY™ Endoprosthesis for Treatment of Stenosis or Occlusion Within the Dialysis Outflow Circuit of an Arteriovenous), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05062291 active not recruitingnot on this map

Prospective, Multicenter, Observational Study to Evaluate the Merit WRAPSODY™ Endoprosthesis for Treatment of Stenosis or Occlusion Within the Dialysis Outflow Circuit of an Arteriovenous (AVF) Fistula or AV Graft (AVG) (The WRAP Registry)

TypeobservationalSponsorMerit Medical Systems, Inc.Ran2022 to 2027Enrolled500ConditionsVenous Stenosis, Venous OcclusionArmsMerit WRAPSODY Endovascular Stent Graft
3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 2 countries.

Dheeraj K RajanDepartment of Medical Imaging, University Medical Imaging Toronto/University of Toronto, University Health Network, 585 University Avenue, 1-PMB-287, Toronto, ON, M5G 2N2, Canada. Dheeraj.Rajan@uhn.ca.ORCID http://orcid.org/0000-0001-9291-6195
Panagiotis M KitrouInterventional Radiology, Patras University Hospital, Patras, Greece.
General University Hospital of Patras · GRUniversity Health Network · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDysfunctional vascular access due to stenosis/occlusion within the arteriovenous fistula or graft (AVF/AVG) negatively affects the clinical management of patients undergoing hemodialysis. Results from the feasibility study of the WRAPSODY™ Cell-Impermeable Endoprosthesis demonstrated that the device can achieve high patency rates and maintain integrity of the dialysis outflow circuit. This study was designed to assess real-world evidence of safety and efficacy outcomes following device placement. MATERIALS AND

methodsThis is a prospective, multicenter, non-investigational, post-market observational study of 500 patients at up to 50 centers worldwide with a mature AVF/AVG dialysis access (≥ 1 hemodialysis session) who experience stenosis/occlusion of the outflow circuit prior to placement of WRAPSODY. Patients will be divided into the following two cohorts: peripheral or central thoracic. Primary outcome measures include target lesion primary patency (TLPP) at 6 months and procedure and/or device-related events through 30 days post-procedure. Secondary outcome measures include TLPP, safety events, and the number of interventions needed to maintain patency through the 24 month study period. Exploratory endpoints include time to access abandonment, resumption of successful dialysis, functional patency, and pending available imaging data, any incidence of stent fractures, migration, or edge stenosis. Study enrollment began in June 2022, the last patient visit is expected in 2026. DISCUSSION: It is expected that this study will provide real-world evidence regarding the performance of the WRAPSODY device in a diverse population of patients, which may encourage its use in the continuum of hemodialysis access management.

trial registrationNCT05062291.

Indexed as

Arteriovenous FistulaRenal DialysisConstriction, PathologicHumansProspective StudiesRegistriesStentsHemodialysisOcclusionPatencyStenosisWRAPSODY Cell-Impermeable Endoprosthesis

Identifiers

PMID37592020
PMCPMC10533592
OpenAlexW4385927891

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials