Evidence map›Paper›PMID 37591881›Full record

ArticleNature communications2023

Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure.

Jian Li, Huiling Jia, Jingkun Zhou, Xingcan Huang, Long Xu, Shengxin Jia, Zhan Gao, Kuanming Yao, Dengfeng Li, Binbin Zhang and 16 more

Abstract read
In one paragraph

Article in Nature communications, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 70 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
70citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

70 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Article
  10. Wearable Tailored Passive Radiative Cooling Textile for Flexible Electronic Integration.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  11. Article
  12. Article
  13. Intrinsic PPG-ECG Coupling for Accurate and Low-Power Blood Pressure Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  14. Review
  15. Article
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article

10 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

26 authors.

Jian Li *Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0002-9768-0932
Huiling Jia *Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0001-7918-0945
Jingkun Zhou *Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0001-5394-4388
Xingcan Huang *Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0003-4210-2470
Long XuSchool of Mechanical and Aerospace Engineering, Jilin University, 130012, Changchun, China.
Shengxin JiaDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0002-6998-3872
Zhan GaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Kuanming YaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0001-8744-8892
Dengfeng LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0002-8875-6974
Binbin ZhangDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Yiming LiuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0003-0134-1934
Ya HuangDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0002-0965-8226
Yue HuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Guangyao ZhaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Zitong XuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Jiyu LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Chun Ki YiuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Yuyu GaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Mengge WuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0002-8116-5717
Yanli JiaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0002-4786-9577
Qiang ZhangDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Xuecheng TaiHong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China.ORCID http://orcid.org/0000-0003-3359-9104
Raymond H ChanDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
Yuanting ZhangDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.ORCID http://orcid.org/0000-0003-4150-5470
Xiaohui MaDepartment of vascular and endovascular surgery, The first medical center of Chinese PLA General Hospital, 100853, Beijing, China. maxiaohui@301hospital.com.cn.
Xinge YuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, China. xingeyu@cityu.edu.hk.ORCID http://orcid.org/0000-0003-0522-1171

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous monitoring of arterial blood pressure (BP) outside of a clinical setting is crucial for preventing and diagnosing hypertension related diseases. However, current continuous BP monitoring instruments suffer from either bulky systems or poor user-device interfacial performance, hampering their applications in continuous BP monitoring. Here, we report a thin, soft, miniaturized system (TSMS) that combines a conformal piezoelectric sensor array, an active pressure adaptation unit, a signal processing module, and an advanced machine learning method, to allow real wearable, continuous wireless monitoring of ambulatory artery BP. By optimizing the materials selection, control/sampling strategy, and system integration, the TSMS exhibits improved interfacial performance while maintaining Grade A level measurement accuracy. Initial trials on 87 volunteers and clinical tracking of two hypertension individuals prove the capability of the TSMS as a reliable BP measurement product, and its feasibility and practical usability in precise BP control and personalized diagnosis schemes development.

Indexed as

HypertensionWearable Electronic DevicesArterial PressureArteriesBlood PressureHumans

Identifiers

PMID37591881
PMCPMC10435523

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.